Detail Specifications
Speed Adjustments:
Single speed
Environmental Protection:
Waterproof
Ambient Tempurature At Full Rated Power:
480.0 degrees fahrenheit
Operating Speed At Rated Capacity In Rpm:
3460.0
Electrical Connection Type:
Terminal block
Static Pressure At Specificationified Air Flow Rate:
7.0 inches of water
Prime Mover Type:
Steam turbine
Inclosure Type:
Fully enclosed
Mounting Facility Type And Quantity:
1 flange
Rotation Direction For Which Designed:
Counterclockwise
Air Flow Rate:
8400.000 cubic feet per minute
Prime Mover Power Rating:
21.100 horsepower
Discharge Direction:
Horizontal
Surface Treatment:
Zinc blade
Surface Treatment:
Zinc housing inside
Surface Treatment:
Zinc housing outside
Reference Number Differentiating Characteristics:
As differentiated by ajlg
Item Name:
Fan,engine Cooling
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC