Product Technical Spec.
Cooling System Coolant Flow Rate:
0.3 gallons per minute
Overall Length:
7.000 inches
Overall Width:
3.000 inches
Body Diameter:
3.000 inches
Frequency Range Rating:
+8.900/+9.400 gigahertz
Voltage Standing Wave Ratio:
1.15
Power Rating:
1.000 kilowatts average
Voltage Standing Wave Ratio Frequency Range:
+8.900/+9.400 gigahertz
Termination Type:
Waveguide flange
Waveguide Flange Designation:
Aug-1358/u
Operating Position:
Horizontal
Internal Operating Pressure:
15.0 pounds per square inch gage
Coolant Chamber Pressure:
100.0 pounds per square inch gage
Input Coolant Temp:
30.0 degrees celsius
Cooling Method:
Forced liquid
Style Designator:
Waveguide mounted
Item Name:
Resistor Shunt Patch
Cross Referenced Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC