Product Technical Spec.
Cooling System Coolant Flow Rate:
6.0 gallons per minute
Impedance Rating In Ohms:
50.0
Frequency Range Rating:
+0.000/+500.000 kilohertz and +500.000/+700.000 kilohertz and +700.000/+800.000 kilohertz
Voltage Standing Wave Ratio:
1.10 and 1.15 and 1.30
Power Rating:
15.000 kilowatts peak
Voltage Standing Wave Ratio Frequency Range:
+0.000/+500.000 kilohertz and +500.000/+700.000 kilohertz and +700.000/+800.000 kilohertz
Termination Type:
Coaxial line flange
Coaxial Line Flange Size:
5.188 inches
Intake Connection Thread Location:
External
Discharge Connection Thread Location:
External
Operating Position:
All positions
Discharge Connection Thread Size And Series/type Designator:
3/4-14 npsh
Intake Connection Thread Size And Series/type Designator:
3/4-14 npsh
Coaxial Line Flange Type:
Rigid
Cooling Method:
Forced liquid
Cross Referenced Parts