Solid state, two position; rf power, +17 dbm min operating peak or cw; +21 dbm min non-destruct peak or cw; third order intercept, +55 dbm min.; input/output isolation, 75 dbm min. With switch in open; cross isolation, 75 db min, (j2 to j3); directivity, 20 dbm ; rfi; control signal, a differential two sttate voltage (ttl) input; pulse width, 3 microseconds; switching rate, dc to 2500 pps; decoupling filters; temperature, operating, 0 deg.C. To +50 deg.C., nonoperating, minus 35 deg.C. To +60 deg.C.; humidity, operating, 15 to 80%; nonoperating, 15 to 90%; altitude up to 3300 meters above mean sea level
NSN 6610-01-415-1623
NSN 5920-01-379-7475
NSN 6620-00-243-7766
NSN 5925-01-495-3102
NSN 6145-00-398-4405
NSN 6110-01-445-8189
NSN 6130-00-235-3479
NSN 5910-00-107-0771
NSN 5945-00-753-5127
NSN 5835-01-013-9321
NSN 5950-00-051-7461
NSN 5975-01-176-3615
Last Updated: 06/07/2024