Detail Specifications
Overall Length:
4.290 inches
Frequency Rating:
0.0 gigahertz single frequency crosstalk reference and 10.0 gigahertz single frequency crosstalk reference
Frequency Rating:
0.0 gigahertz single frequency insertion loss reference and 10.0 gigahertz single frequency insertion loss reference
Frequency Rating:
0.0 gigahertz single frequency operating and 10.0 gigahertz single frequency operating
Frequency Rating:
0.0 gigahertz single frequency rf power handling and 10.0 gigahertz single frequency rf power handling
Frequency Rating:
0.0 gigahertz single frequency voltage standing wave ratio and 10.0 gigahertz single frequency voltage standing wave ratio
Frequency Rating:
0.0 gigahertz and 10.0 gigahertz single frequency insertion loss reference
Frequency Rating:
0.0 gigahertz and 10.0 gigahertz single frequency operating
Frequency Rating:
0.0 gigahertz and 10.0 gigahertz single frequency rf power handling
Frequency Rating:
0.0 gigahertz and 10.0 gigahertz single frequency voltage standing wave ratio
Frequency Rating:
0.0 gigahertz and 10.0 gigahertz single frequency crosstalk reference
Overall Diameter:
5.000 inches
Unthreaded Mounting Hole Diameter:
0.189 inches
Longest Horizontal Distance Between Mounting Centers:
2.500 inches single mounting facility pattern
Longest Vertical Distance Between Mounting Centers:
2.500 inches single mounting facility pattern
Operating Tempurature Range:
-55.0/+85.0 degrees celsius
Voltage Standing Wave Ratio:
1.50 single
Insertion Loss In Decibels:
0.52 single
Coaxial Connector Series Designation:
N
Connector End Design:
Female
Rf Power Handling Capability:
100.0 watts average single
Minimum Crosstalk Rating In Decibels:
25.0 single
Actuator Operating Method:
Manual
Switch Operation Sequence:
Breaks before makes
Coupling Position Quantity:
3
Mounting Facility Type And Quantity:
4 unthreaded hole
Mounting Facility Pattern:
Four position rectangular single mounting facility pattern
Surface Treatment:
Anodize body outside surfaces
Test Data Document:
81349-mil-s-3928 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
Terminal Type And Quantity:
3 receptacle, coaxial
Item Name:
Transfer Switch,coaxial
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC