Product Technical Spec.
Overall Length:
3.438 inches
Outside Diameter:
0.375 inches
Conductor Size:
114.0 mcm
End Application:
An/gpa-27a
Power Rating:
3.0 kilowatts average
Characteristic Impedance In Ohms:
50.0
Termination Identification:
Part no. 2664-10a224
Conductor Material:
Copper
Capacitance In Picofarads Per Unit Length:
23.0 per foot
Outer Conductor:
Included
Insulation Spacer Material:
Plastic, polyethylene
Insulation Spacer Outside Diameter:
0.182 inches
Termination Controlling Agency:
Airborne instruments laboratory
Terminal Fitting:
Not included
Accommodated Conductor Type:
Coaxial
Conductor Surface Treatment:
Varnish
Fsc Application Data:
Radar set group, nonairborne except fire control and guided missile
Item Name:
Fixed Air Lines
Cross Referenced Parts
No other part numbers with same form, fit, and function found.