Detail Specifications
Overall Length:
9.000 inches
Outside Diameter:
0.206 inches
Characteristic Impedance In Ohms:
53.5
Termination Identification:
No. Ug-88/u
Conductor Material:
Copper
Capacitance In Picofarads Per Unit Length:
28.5 per foot
Operating Voltage Rating:
1.9 kilovolts
Outer Conductor:
Included
Insulation Spacer Material:
Plastic, polyethylene
Insulation Spacer Outside Diameter:
0.116 inches
Termination Controlling Agency:
Jcens
Terminal Fitting:
Not included
Accommodated Conductor Type:
Coaxial
Conductor Surface Treatment:
Silver
Surface Treatment:
Tinned
Item Name:
Adapter,coaxial,rf
Manufacturer Part Numbers
No other part numbers with same form, fit, and function found.