Detail Specifications
Cross Sectional Shape:
Internal, rectangular external, rectangular
Tubing Wall Construction Style:
Seamless all tubing segment
Voltage Standing Wave Ratio:
1.06
Maximum Operating Pressure:
30.0 pounds per square inch gage
Waveguide Longer Offset Distance:
3.125 inches
Flange Connecting Facility And Quantity:
10 unthreaded hole all flanges all connection facilities
Flange Style:
Contact type all flanges
Waveguide Offset Distance:
2.437 inches
Flexibility:
Rigid all tubing segment
Surface Treatment:
Chromate all tubing segment and flange all surfaces
Style Designator:
Bend type
Fsc Application Data:
Antennas, waveguides, and related equipment
Item Name:
Waveguide Details
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC