Waveguide Assemblies

NSN and commercial parts catalog. 10727 total part numbers. Page 172 of 430
119370-1 NSN 5985-01-061-7515
Product Features:
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • Flange Quantity: 2
  • Voltage Standing Wave Ratio: 1.27
  • Insertion Loss In Decibels: 0.25
  • Maximum Operating Pressure: 30.0 pounds per square inch gage
  • Cage Code: 66544
104X01 NSN 5985-01-062-1590
Product Features:
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • Bend Angle In Deg: 90.0 single bend h-plane
  • Waveguide Longer Offset Distance: 1.750 inches
  • Waveguide Offset Distance: 1.750 inches
  • Flexibility: Rigid single tubing segment
  • Cage Code: 09434
790-2 NSN 5985-01-062-2091
Product Features:
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • Tubing Wall Construction Style: Seamless single tubing segment
  • Flange Quantity: 2
  • Waveguide Outside Width: Between 0.699 inches and 0.705 inches
  • Waveguide Inside Width: Between 0.620 inches and 0.625 inches
  • Cage Code: 00443
TL57101-3.62 NSN 5985-01-062-3460 Alternates: G128-159-001
Product Features:
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • Tubing Wall Construction Style: Interlocked single tubing segment
  • Flange Quantity: 2
  • Flange Inside Width: 0.705 inches all flanges
  • Flange Inside Height: 0.394 inches all flanges
  • Cage Code: 06351
3196708-1-101 NSN 5985-01-062-3783
Product Features:
  • Flange Quantity: 2
  • Special Features: 101 degrees phase angle
  • Style Designator: Bend type
  • Cage Code: 82577
774-9184-009 NSN 5985-01-062-4259
Product Features:
  • Description: Waveguide Assembly
  • Cage Code: 13499
50-800275 NSN 5985-01-062-4512
Product Features:
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • Bend Angle In Deg: 90.0 single bend h-plane
  • Tubing Wall Construction Style: Seamless single tubing segment
  • Flange Quantity: 2
  • Voltage Standing Wave Ratio: 1.05
  • Cage Code: 53613
50-800272 NSN 5985-01-062-4513
Product Features:
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • Tubing Wall Construction Style: Seamless single tubing segment
  • Flange Quantity: 2
  • Flange Inside Width: 0.622 inches all flanges
  • Flange Inside Height: 0.311 inches all flanges
  • Cage Code: 53613
50-800274 NSN 5985-01-062-4514
Product Features:
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • Bend Angle In Deg: 90.0 single bend e-plane
  • Tubing Wall Construction Style: Seamless single tubing segment
  • Flange Quantity: 2
  • Flange Inside Width: 0.622 inches all flanges
  • Cage Code: 53613
TS41136 NSN 5985-01-062-7625 Alternates: 32-87857-5
Product Features:
  • Description: Waveguide Assembly
  • Cage Code: 06351
2665868 NSN 5985-01-062-7915
Product Features:
  • Flange Quantity: 2
  • Voltage Standing Wave Ratio: 1.03
  • Waveguide Length: 32.500 inches
  • Style Designator: Straight type
  • Cage Code: 10001
774-9404-010 NSN 5985-01-062-8540
Product Features:
  • Description: Waveguide Assembly
  • Cage Code: 13499
774-9404-013 NSN 5985-01-062-8541
Product Features:
  • Description: Waveguide Assembly
  • Cage Code: 13499
774-9451-026 NSN 5985-01-062-8542
Product Features:
  • Description: Waveguide Assembly
  • Cage Code: 13499
774-9451-030 NSN 5985-01-062-8543
Product Features:
  • Description: Waveguide Assembly
  • Cage Code: 13499
774-9451-032 NSN 5985-01-062-8544
Product Features:
  • Description: Waveguide Assembly
  • Cage Code: 13499
30-800252 NSN 5985-01-062-9419
Product Features:
  • Cross Sectional Shape: Internal, elliptical external, round
  • Tubing Wall Construction Style: Corrugated single tubing segment
  • Flange Quantity: 2
  • Flexibility: Flexible single tubing segment
  • Style Designator: Straight type
  • Cage Code: 53613
17-15849-1 NSN 5985-01-062-9420
Product Features:
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • Bend Angle In Deg: 45.0 all bends h-plane
  • Tubing Wall Construction Style: Seamless single tubing segment
  • Flange Quantity: 2
  • Voltage Standing Wave Ratio: 1.08
  • Cage Code: 04614
119370-2 NSN 5985-01-063-0057
Product Features:
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • Flange Quantity: 2
  • Voltage Standing Wave Ratio: 1.27
  • Insertion Loss In Decibels: 0.25
  • Maximum Operating Pressure: 30.0 pounds per square inch gage
  • Cage Code: 66544
336-730001-401 NSN 5985-01-063-6255
Product Features:
  • Cross Sectional Shape: Internal, rectangular external, round
  • Flange Quantity: 4
  • Flange Inside Width: 1.437 inches second flange
  • Flange Inside Height: 0.781 inches second flange
  • Flange Depth: 0.438 inches first flange
  • Cage Code: 90073
50-800273 NSN 5985-01-063-6477
Product Features:
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • Bend Angle In Deg: 90.0 single bend h-plane
  • Tubing Wall Construction Style: Seamless single tubing segment
  • Flange Quantity: 2
  • Flange Inside Width: 0.750 inches all flanges
  • Cage Code: 53613
50-800362 NSN 5985-01-063-6478
Product Features:
  • Flange Quantity: 2
  • Flange Outside Width: 3.000 inches all flanges
  • Flange Outside Height: 3.000 inches all flanges
  • Voltage Standing Wave Ratio: 1.05
  • Insertion Loss In Decibels: 0.05
  • Cage Code: 53613
50-800088 NSN 5985-01-063-6479
Product Features:
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • Tubing Wall Construction Style: Seamless single tubing segment
  • Flange Quantity: 2
  • Flange Inside Width: 0.622 inches all flanges
  • Flange Inside Height: 0.311 inches all flanges
  • Cage Code: 53613
50-800366 NSN 5985-01-063-6480
Product Features:
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • Tubing Wall Construction Style: Seamless all tubing segment
  • Flange Quantity: 2
  • Flange Inside Width: 0.622 inches all flanges
  • Flange Inside Height: 0.311 inches all flanges
  • Cage Code: 53613
2921031 NSN 5985-01-063-6481 Alternates: 1051794
Product Features:
  • Cross Sectional Shape: Internal, rectangular external, rectangular
  • End Application: Missile guidance and tracking set an/spg055b
  • Tubing Wall Construction Style: Seamless single tubing segment
  • Flange Quantity: 2
  • Maximum Operating Pressure: 8.0 pounds per square inch gage
  • Cage Code: 10001