#11268812 Line Protective Switch 4.359 inches center to center distance between terminals parallel to length

11268812

Circuit Breaker

NSN 5925-00-139-4829

DEMIL
Shelf Life
UOM
NIIN
Demil:
NO
Shelf Life:
N/A
UOM:
1 EA
NIIN:
001394829
Description

Multipole-single actuator type body style, 5.260 inches body length, 2.984 inches body width, metal case material, 4.359 inches center to center distance between terminals parallel to length.

Technical Specifications of NSN

Body Style:
Multipole-single actuator type
Body Length:
5.260 inches
Body Width:
2.984 inches
Case Material:
Metal
Center To Center Distance Between Terminals Parallel To Length:
4.359 inches
Center To Center Distance Between Terminals Parallel To Width:
0.490 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
3.062 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
1.000 inches
End Application:
Asr7
Boss Height:
0.219 inches
Mounting Surface To Terminal End Distance:
3.313 inches
Pole Quantity:
3
Mounting Facility Type And Quantity:
4 threaded hole
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
8.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts:
250.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
5000.0 ac all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic all locations
Trip Release Characteristic:
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 all locations
Reset Method:
Manual
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
1 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At pole two
Internal Trip Release Configuration:
Series trip all locations
Thread Size:
0.190 inches
Trip Delay Time In Seconds Per Rated Continuous Current:
0.700 at 150 pct all locations and 1.200 at 150 pct all locations and 0.300 at 200 pct all locations and 0.900 at 200 pct all locations and 0.150 at 300 pct all locations and 0.300 at 300 pct all locations
Inclosure Protection Type For Which Designed:
Fungus resistant and moisture resistant
Frequency In Hertz:
60.0 all locations
Thread Series Designator:
Unf
Terminal Type And Quantity:
6 threaded stud
NSN:
5925-00-139-4829
Item Name:
Line Protective Switch
Cage Code:
17773

Other Related Parts

Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC
Part Number:
3363SMG4-8-250VAC60C3
Cage Code:
74193
RNCC:
5
RNVC:
9
RNAAC:
BR
Status:
A
MSDS:
SADC:

  We Guarantee with Every Order

  •   100% Genuine Manufacturers Parts
  •   Every Product thoroughly Inspected
  •   Sales Record Retention of 7 years
  •   Fast Delivery
  •   HAZMAT Certified
  •   Global Shipping

Pricing & Availability

Submit this form for current pricing and availability quote on part number 11268812 and/or cross reference parts.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:

We do not share or sell your information to anyone.
Privacy | Terms

Catalog Drilldown
--- Electrical And Electronic Equipment Components
------ Circuit Breakers
--------- Circuit Breakers
------------ P/N 11268812

New Products Recently updated in circuit breakers

  • 27-10388-1 circuit breaker
    NSN 5925-00-166-3440

    Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height

  • 1536-007-10 circuit breaker
    NSN 5925-00-166-3440

    Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height

  • 314C920G21 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • KA3150 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • 504C336G21 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • BAB1015 circuit breaker
    NSN 5925-00-165-8694

    1 pole quantity, 15.0 amperes ac single location maximum continuous load current rating per pole, 240.0 ac single location operating voltage type and rating per pole in volts