Medical repair part for 6640007650621; water bath, electric; fscm 95632; part no. 330-119-00; circuit breaker; fscm 95632; part no. 330-119-00; 10 amps rated
Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height
Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height
3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts
3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts
3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts
1 pole quantity, 15.0 amperes ac single location maximum continuous load current rating per pole, 240.0 ac single location operating voltage type and rating per pole in volts
NSN 5915-01-467-9048
NSN 5975-01-359-4848
NSN 6105-01-272-4707
NSN 5920-01-157-9471
NSN 5920-01-434-8504
NSN 6620-01-478-9667
NSN 6320-01-195-5583
NSN 6610-00-722-7472
NSN 6645-00-269-8440
NSN 7035-00-908-4933
NSN 5920-00-102-3792
NSN 5915-01-005-0164