Detail Specifications
Body Style:
Multipole-multiple actuator type
Body Length:
Between 2.490 inches and 2.510 inches
Body Width:
Between 1.490 inches and 1.510 inches
Center To Center Distance Between Terminals Parallel To Length:
Between 1.928 inches and 1.948 inches
Center To Center Distance Between Terminals Parallel To Width:
Between 0.740 inches and 0.760 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 2.052 inches and 2.072 inches
Switch Contact Arrangement:
Single pole, double throw
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
Between 0.740 inches and 0.760 inches
Fragility Factor:
Moderately rugged
Boss Height:
Between 0.130 inches and 0.150 inches
Mounting Surface To Terminal End Distance:
2.471 inches
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
4 threaded hole
Storage Type:
General purpose warehouse
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
10.0 amperes ac first location
Maximum Continuous Load Current Rating Per Pole:
8.0 amperes ac second location
Operating Voltage Type And Rating Per Pole In Volts:
250.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
1000.0 ac all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic all locations
Auxiliary Trip Coil Voltage Type And Rating In Volts:
115.0 ac second location
Trip Release Characteristic:
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 all locations
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
2 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At each pole
External Actuator Linkage Arrangement:
One and two linked
Auxiliary Switch Function And Quantity:
1 alarm
Internal Trip Release Configuration:
Series trip first location
Internal Trip Release Configuration:
Series trip w/remote trip feature second location
Thread Size:
0.138 inches
Trip Release Duty Cycle:
Continuous second location
Switch Location And Position Designation:
External at pole one
Trip Delay Time In Seconds Per Rated Continuous Current:
3.000 at 200 pct all locations and 80.000 at 200 pct all locations
Inclosure Protection Type For Which Designed:
Moisture resistant and salt water resistant and humidity resistant
Switch Terminal Type:
Tab, solder lug
Switch Current Rating And Type In Amps:
10.0 ac and 4.0 dc
Switch Voltage Rating And Type In Volts:
250.0 ac and 30.0 dc
Frequency In Hertz:
50.0 all locations or 60.0 all locations
Thread Series Designator:
Unc
Terminal Type And Quantity:
5 threaded stud
Item Name:
Thermal Magnetic Trip Breaker