#2567-249 Magnetic Circuit Protector | Circuit Breakers

2567-249

Circuit Breaker

NSN 5925-01-161-2945

DEMIL
Shelf Life
UOM
NIIN
Demil:
NO
Shelf Life:
N/A
UOM:
EA
NIIN:
011612945

Technical Specifications of NSN

Body Style:
Multipole-multiple actuator type
Body Length:
Between 5.769 inches and 5.831 inches
Body Width:
Between 2.041 inches and 2.103 inches
Case Material:
Plastic
Center To Center Distance Between Terminals Parallel To Length:
Between 3.516 inches and 3.578 inches
Center To Center Distance Between Terminals Parallel To Width:
Between 0.995 inches and 1.057 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 2.719 inches and 2.781 inches
Switch Contact Arrangement:
Single pole, double throw
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
Between 0.995 inches and 1.057 inches
Fragility Factor:
Moderately rugged
Boss Height:
Between 0.209 inches and 0.229 inches
Mounting Surface To Terminal End Distance:
Between 3.172 inches and 3.265 inches
Pole Quantity:
2
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
4 threaded hole
Storage Type:
General purpose warehouse
Special Handling Feature:
Magnetic
Features Provided:
High inrush protection
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
15.0 amperes ac first location
Operating Voltage Type And Rating Per Pole In Volts:
24.0 dc second location
Operating Voltage Type And Rating Per Pole In Volts:
240.0 ac first location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
5000.0 ac first location
Circuit Protection Type:
Overcurrent first location
Circuit Protection Type:
Overvoltage second location
Trip Release Method:
Magnetic-hydraulic first location
Trip Release Characteristic:
Instantaneous second location
Trip Release Characteristic:
Time delay first location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 first location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
120.0 second location
Reset Method:
Manual
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
2 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At each pole
External Actuator Linkage Arrangement:
One and two linked
Auxiliary Switch Function And Quantity:
1 alarm
Internal Trip Release Configuration:
Series trip first location
Internal Trip Release Configuration:
Relay trip second location
Thread Size:
0.138 inches
Switch Location And Position Designation:
External at pole one
Trip Delay Time In Seconds Per Rated Continuous Current:
15.000 at 200 pct first location and 70.000 at 200 pct first location
Inclosure Protection Type For Which Designed:
Dustproof
Switch Terminal Type:
Turret
Switch Current Rating And Type In Amps:
2.5 ac and 1.0 dc
Switch Voltage Rating And Type In Volts:
250.0 ac and 50.0 dc
Frequency In Hertz:
50.0 first location or 60.0 first location
Unpackaged Unit Weight:
11.000 ounces
Thread Series Designator:
Unc
Terminal Type And Quantity:
6 threaded stud
NSN:
5925-01-161-2945
Item Name:
Magnetic Circuit Protector
Cage Code:
74006

Other Related Parts

Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC
Part Number:
2567-249-00
Cage Code:
06434
RNCC:
C
RNVC:
1
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
AC
Part Number:
CD2-A9-A16-DU
Cage Code:
74193
RNCC:
5
RNVC:
9
RNAAC:
TX
Status:
A
MSDS:
SADC:

  We Guarantee with Every Order

  •   100% Genuine Manufacturers Parts
  •   Every Product thoroughly Inspected
  •   Sales Record Retention of 7 years
  •   Fast Delivery
  •   HAZMAT Certified
  •   Global Shipping

Pricing & Availability

Submit this form for current pricing and availability quote on part number 2567-249 and/or cross reference parts.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:

We do not share or sell your information to anyone.
Privacy | Terms

Catalog Drilldown
--- Electrical And Electronic Equipment Components
------ Circuit Breakers
--------- Circuit Breakers
------------ P/N 2567-249

New Products Recently updated in circuit breakers

  • 27-10388-1 circuit breaker
    NSN 5925-00-166-3440

    Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height

  • 1536-007-10 circuit breaker
    NSN 5925-00-166-3440

    Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height

  • 314C920G21 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • KA3150 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • 504C336G21 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • BAB1015 circuit breaker
    NSN 5925-00-165-8694

    1 pole quantity, 15.0 amperes ac single location maximum continuous load current rating per pole, 240.0 ac single location operating voltage type and rating per pole in volts


Best-Selling Products A collection of our most popular products

Last Updated: 06/30/2024