#ATB22030 Input Mains Breaker Deon arc quenching method

ATB22030

Circuit Breaker

NSN 5925-00-066-6890

DEMIL
Shelf Life
UOM
NIIN
Demil:
NO
Shelf Life:
UOM:
NIIN:
000666890

Product Features

Mtg holes 0n 7.250 in. By 1.375 in. Mtg centers

Description

9.380 inches overall length, 2.750 inches overall height, 4.690 inches overall width, plastic case material, 2 pole quantity, Deon arc quenching method.

Detail Specifications

Overall Length:
9.380 inches
Overall Height:
2.750 inches
Overall Width:
4.690 inches
Case Material:
Plastic
Pole Quantity:
2
Arc Quenching Method:
Deion
Mounting Facility Type And Quantity:
4 unthreaded hole
Maximum Continuous Load Current Rating Per Pole:
30.0 amperes ac all locations and 30.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts:
250.0 ac all locations and 250.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
5000.0 ac all locations and 5000.0 dc all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Thermal-magnetic all locations
Trip Release Characteristic:
Instantaneous all locations and time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
117.0 all locations
Reset Method:
Manual
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
1 toggle
Actuator Function:
Trip w/separate reset
Thread Size:
0.281 inches
Trip Delay Time In Seconds Per Rated Continuous Current:
75.000 at 150 pct all locations and 360.000 at 150 pct all locations and 20.000 at 200 pct all locations and 63.000 at 200 pct all locations and 8.000 at 300 pct all locations and 15.000 at 300 pct all locations and 4.000 at 400 pct all locations and 8.000 at 400 pct all locations and 2.500 at 500 pct all locations and 4.500 at 500 pct all locations and 0.030 at 1100 pct all locations and 1.000 at 1100 pct all locations and 0.010 at 2000 pct all locations and 0.020 at 2000 pct all locations
Inclosure Protection Type For Which Designed:
Dustproof
Trip Release Ambient Tempurature Rating:
25.0 degrees celsius all locations
Frequency In Hertz:
60.0 all locations
Terminal Type And Quantity:
4 screw
NSN:
5925-00-066-6890
Item Name:
Breaker,input Mains
Cage Code:
24446

Manufacturer Part Numbers

Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC
Part Number:
ATB22030
Cage Code:
60969
RNCC:
3
RNVC:
2
RNAAC:
XX
Status:
A
MSDS:
SADC:

  We Guarantee with Every Order

  •   100% Genuine Manufacturers Parts
  •   Every Product thoroughly Inspected
  •   Sales Record Retention of 7 years
  •   Fast Delivery
  •   HAZMAT Certified
  •   Global Shipping

Pricing & Availability

Submit this form for current pricing and availability quote on part number atb22030 and/or cross reference parts.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:

We do not share or sell your information to anyone.
Privacy | Terms

Catalog Drilldown
--- Electrical And Electronic Equipment Components
------ Circuit Breakers
--------- Circuit Breakers
------------ P/N ATB22030

New Products Recently updated in circuit breakers

  • 27-10388-1 circuit breaker
    NSN 5925-00-166-3440

    Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height

  • 1536-007-10 circuit breaker
    NSN 5925-00-166-3440

    Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height

  • 314C920G21 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • KA3150 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • 504C336G21 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • BAB1015 circuit breaker
    NSN 5925-00-165-8694

    1 pole quantity, 15.0 amperes ac single location maximum continuous load current rating per pole, 240.0 ac single location operating voltage type and rating per pole in volts


Best-Selling Products A collection of our most popular products