Product Features
Four terminals on pole one
Detail Specifications
Body Style:
Multipole-multiple actuator type
Mounting Slot Width:
0.164 inches
Body Length:
5.844 inches
Center To Center Distance Between Terminals Parallel To Length:
3.546 inches
Center To Center Distance Between Terminals Parallel To Width:
1.032 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
2.750 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
1.032 inches
Fragility Factor:
Moderately rugged
Boss Height:
0.218 inches
Mounting Surface To Terminal End Distance:
2.609 inches
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
8 threaded hole and 8 slot
Storage Type:
General purpose warehouse
Special Handling Feature:
Magnetic
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
60.0 amperes ac fourth location
Maximum Continuous Load Current Rating Per Pole:
60.0 amperes ac second location
Maximum Continuous Load Current Rating Per Pole:
60.0 amperes ac third location
Operating Voltage Type And Rating Per Pole In Volts:
107.0 dc first location
Operating Voltage Type And Rating Per Pole In Volts:
240.0 ac fourth location
Operating Voltage Type And Rating Per Pole In Volts:
240.0 ac second location
Operating Voltage Type And Rating Per Pole In Volts:
240.0 ac third location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
5000.0 ac third location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
5000.0 ac fourth location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
5000.0 ac second location
Circuit Protection Type:
Overcurrent fourth location
Circuit Protection Type:
Overcurrent second location
Circuit Protection Type:
Overcurrent third location
Circuit Protection Type:
Undervoltage first location
Trip Release Method:
Magnetic first location
Trip Release Method:
Magnetic-hydraulic fourth location
Trip Release Method:
Magnetic-hydraulic second location
Trip Release Method:
Magnetic-hydraulic third location
Trip Release Characteristic:
Instantaneous first location
Trip Release Characteristic:
Time delay fourth location
Trip Release Characteristic:
Time delay second location
Trip Release Characteristic:
Time delay third location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
140.0 fourth location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
140.0 second location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
140.0 third location
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
4 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At each pole
External Actuator Linkage Arrangement:
One, two, three, and four linked
Internal Trip Release Configuration:
Series trip all locations
Thread Size:
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current:
4.000 at 200 pct fourth location and 10.000 at 200 pct fourth location
Trip Delay Time In Seconds Per Rated Continuous Current:
4.000 at 200 pct second location and 10.000 at 200 pct second location
Trip Delay Time In Seconds Per Rated Continuous Current:
4.000 at 200 pct third location and 10.000 at 200 pct third location
Inclosure Protection Type For Which Designed:
Fungus resistant and moisture resistant
Frequency In Hertz:
400.0 fourth location
Frequency In Hertz:
400.0 second location
Frequency In Hertz:
400.0 third location
Test Data Document:
49956-g166010 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
Thread Series Designator:
Unc
Terminal Type And Quantity:
10 threaded stud
Item Name:
Tri-break Fused Circuit Breaker
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC