Description
Multipole-multiple actuator type body style, 0.164 inches mounting slot width, 5.844 inches body length, 3.096 inches body width.
Product Technical Spec.
Body Style:
Multipole-multiple actuator type
Mounting Slot Width:
0.164 inches
Body Length:
5.844 inches
Center To Center Distance Between Terminals Parallel To Length:
3.546 inches
Center To Center Distance Between Terminals Parallel To Width:
1.032 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
2.750 inches
Switch Contact Arrangement:
Single pole, double throw
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
1.032 inches
Fragility Factor:
Moderately rugged
Boss Height:
0.218 inches
Mounting Surface To Terminal End Distance:
2.609 inches
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
8 threaded hole and 8 slot
Storage Type:
General purpose warehouse
Special Handling Feature:
Magnetic
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
50.0 amperes dc third location
Maximum Continuous Load Current Rating Per Pole:
60.0 amperes dc first location
Maximum Continuous Load Current Rating Per Pole:
60.0 amperes dc second location
Operating Voltage Type And Rating Per Pole In Volts:
125.0 dc first location
Operating Voltage Type And Rating Per Pole In Volts:
125.0 dc second location
Operating Voltage Type And Rating Per Pole In Volts:
125.0 dc third location
Operating Voltage Type And Rating Per Pole In Volts:
30.0 dc fourth location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
5000.0 dc all locations
Circuit Protection Type:
Overcurrent first location
Circuit Protection Type:
Overvoltage fourth location
Circuit Protection Type:
Overcurrent second location
Circuit Protection Type:
Overcurrent third location
Trip Release Method:
Magnetic all locations
Trip Release Characteristic:
Instantaneous fourth location
Trip Release Characteristic:
Time delay second location
Trip Release Characteristic:
Time delay third location
Trip Release Characteristic:
Time delay first location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 first location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 second location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 third location
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
4 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At each pole
External Actuator Linkage Arrangement:
One, two, three, and four linked
Auxiliary Switch Function And Quantity:
1 alarm
Internal Trip Release Configuration:
Series trip first location
Internal Trip Release Configuration:
Relay trip fourth location
Internal Trip Release Configuration:
Series trip second location
Internal Trip Release Configuration:
Series trip third location
Thread Size:
0.138 inches
Switch Location And Position Designation:
Internal at pole four
Trip Delay Time In Seconds Per Rated Continuous Current:
45.000 at 200 pct second location and 100.000 at 200 pct second location
Trip Delay Time In Seconds Per Rated Continuous Current:
45.000 at 200 pct third location and 100.000 at 200 pct third location
Trip Delay Time In Seconds Per Rated Continuous Current:
45.000 at 200 pct first location and 100.000 at 200 pct first location
Inclosure Protection Type For Which Designed:
Fungus resistant and moisture resistant
Switch Terminal Type:
Pin
Switch Current Rating And Type In Amps:
5.0 ac
Switch Voltage Rating And Type In Volts:
125.0 ac
Thread Series Designator:
Unc
Terminal Type And Quantity:
10 threaded stud
Item Name:
Breaker,input Mains
Cross Referenced Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC