#NE231050 Tri-break Fused Circuit Breaker 0.188 inches unthreaded mounting hole diameter

NE231050

Circuit Breaker

NSN 5925-00-159-0444

DEMIL
Shelf Life
UOM
NIIN
Demil:
NO
Shelf Life:
UOM:
NIIN:
001590444

Product Features

Mtg holes in 2 rows of 3, 1.375 by 4.844 in. C to c

Description

6.000 inches overall length, 3.969 inches overall height, 4.125 inches overall width, plastic case material, 0.188 inches unthreaded mounting hole diameter.

Detail Specifications

Overall Length:
6.000 inches
Overall Height:
3.969 inches
Overall Width:
4.125 inches
Case Material:
Plastic
Unthreaded Mounting Hole Diameter:
0.188 inches
Pole Quantity:
3
Arc Quenching Method:
Deion
Mounting Facility Type And Quantity:
6 unthreaded hole
Maximum Continuous Load Current Rating Per Pole:
15.0 amperes ac all locations and 15.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts:
250.0 ac all locations and 125.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
5000.0 ac all locations and 5000.0 dc all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Thermal all locations
Trip Release Characteristic:
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 all locations
Ultimate Trip Time Per Pole In Seconds:
210.000 all locations and 4200.000 all locations
Reset Method:
Manual
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
1 toggle
Actuator Function:
Trip w/separate reset
Trip Delay Time In Seconds Per Rated Continuous Current:
210.000 at 125 pct all locations and 4200.000 at 125 pct all locations and 20.000 at 200 pct all locations and 105.000 at 200 pct all locations and 8.000 at 300 pct all locations and 23.000 at 300 pct all locations
Trip Release Ambient Tempurature Rating:
25.0 degrees celsius all locations
Terminal Type And Quantity:
6 screw
NSN:
5925-00-159-0444
Item Name:
Tri-break Fused Circuit Breaker
Cage Code:
79443

Manufacturer Part Numbers

Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC
Part Number:
1532392
Cage Code:
79500
RNCC:
3
RNVC:
2
RNAAC:
XX
Status:
A
MSDS:
SADC:
Part Number:
S1532392
Cage Code:
F0179
RNCC:
3
RNVC:
2
RNAAC:
XX
Status:
A
MSDS:
SADC:
Part Number:
S1532392
Cage Code:
79500
RNCC:
5
RNVC:
2
RNAAC:
XX
Status:
A
MSDS:
SADC:
Part Number:
1532392
Cage Code:
83309
RNCC:
5
RNVC:
9
RNAAC:
TX
Status:
A
MSDS:
SADC:

  We Guarantee with Every Order

  •   100% Genuine Manufacturers Parts
  •   Every Product thoroughly Inspected
  •   Sales Record Retention of 7 years
  •   Fast Delivery
  •   HAZMAT Certified
  •   Global Shipping

Pricing & Availability

Submit this form for current pricing and availability quote on part number ne231050 and/or cross reference parts.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:

We do not share or sell your information to anyone.
Privacy | Terms

Catalog Drilldown
--- Electrical And Electronic Equipment Components
------ Circuit Breakers
--------- Circuit Breakers
------------ P/N NE231050

New Products Recently updated in circuit breakers

  • 27-10388-1 circuit breaker
    NSN 5925-00-166-3440

    Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height

  • 1536-007-10 circuit breaker
    NSN 5925-00-166-3440

    Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height

  • 314C920G21 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • KA3150 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • 504C336G21 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • BAB1015 circuit breaker
    NSN 5925-00-165-8694

    1 pole quantity, 15.0 amperes ac single location maximum continuous load current rating per pole, 240.0 ac single location operating voltage type and rating per pole in volts


Best-Selling Products A collection of our most popular products

Last Updated: 04/19/2024