Undervoltage release mechanism monitors a voltage and trips the mcp when the voltage falls between 70 and 35 percent of the solenoid coil rating
No other part numbers with same form, fit, and function found.
Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height
Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height
3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts
3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts
3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts
1 pole quantity, 15.0 amperes ac single location maximum continuous load current rating per pole, 240.0 ac single location operating voltage type and rating per pole in volts
NSN 5985-00-111-3503
NSN 6110-01-283-4076
NSN 6240-01-648-0661
NSN 6320-00-539-9283
NSN 6685-00-230-4267
NSN 5945-01-512-1066
NSN 2925-00-156-6615
NSN 5915-01-508-5636
NSN 6220-00-938-2931
NSN 6685-01-118-0080
NSN 5855-00-174-3482
NSN 6650-00-413-6619
Last Updated: 08/05/2025