Detail Specifications
Body Style:
Single pole type
Bushing Length:
Between 0.040 inches and 0.055 inches
Body Length:
Between 0.719 inches and 0.781 inches
Body Width:
Between 0.531 inches and 0.593 inches
Center To Center Distance Between Terminals Parallel To Length:
Between 0.469 inches and 0.531 inches
Mounting Surface To Terminal End Distance:
Between 1.281 inches and 1.343 inches
Mounting Facility Type And Quantity:
1 threaded bushing w/panel seal
Storage Type:
General purpose warehouse
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
2.0 amperes ac single location and 2.0 amperes dc single location
Maximum Continuous Load Current Rating Per Pole:
2.0 amperes ac and 2.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts:
120.0 ac single location and
Operating Voltage Type And Rating Per Pole In Volts:
28.0 dc single location
Operating Voltage Type And Rating Per Pole In Volts:
120.0 ac and 28.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
2500.0 ac single location and
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
6000.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
2500.0 ac and 6000.0 dc single location
Circuit Protection Type:
Overcurrent single location
Trip Release Method:
Thermal single location
Trip Release Characteristic:
Time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
138.0 single location
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
1 push-pull
Actuator Function:
Trip-reset
Actuator Position Designation:
At pole one
Internal Trip Release Configuration:
Series trip single location
Thread Size:
0.438 inches
Trip Delay Time In Seconds Per Rated Continuous Current:
16.000 at 200 pct single location
Trip Delay Time In Seconds Per Rated Continuous Current:
4.000 at 200 pct single location and
Trip Delay Time In Seconds Per Rated Continuous Current:
4.000 at 200 pct and 16.000 at 200 pct single location
Inclosure Protection Type For Which Designed:
Fungus resistant
Inclosure Protection Type For Which Designed:
Moisture resistant and
Inclosure Protection Type For Which Designed:
Moisture resistant and fungus resistant
Trip Release Ambient Tempurature Rating:
25.0 degrees celsius single location
Frequency In Hertz:
400.0 single location
Unpackaged Unit Weight:
0.057 pounds
Thread Series Designator:
Uns
Terminal Type And Quantity:
2 tab w/screw
Item Name:
Breaker,circuit
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC