Product Technical Spec.
Body Style:
Multipole-single actuator type
Bushing Length:
Between 0.464 inches and 0.526 inches
Body Length:
Between 1.969 inches and 2.031 inches
Center To Center Distance Between Terminals Parallel To Length:
Between 1.499 inches and 1.561 inches
Center To Center Distance Between Terminals Parallel To Width:
Between 0.735 inches and 0.765 inches
Nonturn Device Location:
At 9 oclock and at 12 oclock
Nonturn Device Radius:
Between 0.641 inches and 0.671 inches
Nonturn Device Length:
Between 0.115 inches and 0.145 inches
Nonturn Device Diameter:
0.138 inches
Switch Contact Arrangement:
Single pole, double throw
Fragility Factor:
Moderately rugged
Mounting Surface To Terminal End Distance:
2.232 inches
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
1 threaded bushing w/panel seal
Storage Type:
General purpose warehouse
Special Handling Feature:
Magnetic
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
2.5 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts:
240.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
1000.0 ac all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic all locations
Trip Release Characteristic:
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 all locations
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
1 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At pole two
Auxiliary Switch Function And Quantity:
1 alarm
Internal Trip Release Configuration:
Series trip all locations
Thread Size:
0.500 inches
Switch Location And Position Designation:
Internal at pole one
Trip Delay Time In Seconds Per Rated Continuous Current:
3.000 at 200 pct all locations and 20.000 at 200 pct all locations
Inclosure Protection Type For Which Designed:
Fungus resistant
Switch Terminal Type:
Tab, solder lug
Switch Current Rating And Type In Amps:
10.0 ac and 2.0 dc
Switch Voltage Rating And Type In Volts:
250.0 ac and 50.0 dc
Frequency In Hertz:
60.0 all locations
Test Data Document:
81349-mil-c-55629 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
Thread Series Designator:
Un
Terminal Type And Quantity:
4 tab w/screw
Specification Data:
81349-mil-c-55629/21 government specification
Item Name:
Thermal Magnetic Trip Breaker
Cross Referenced Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC