Detail Specifications
Body Style:
Multipole-multiple actuator type
Body Length:
Between 5.769 inches and 5.831 inches
Body Width:
Between 2.041 inches and 2.103 inches
Center To Center Distance Between Terminals Parallel To Length:
Between 3.516 inches and 3.578 inches
Center To Center Distance Between Terminals Parallel To Width:
Between 0.995 inches and 1.057 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 2.719 inches and 2.781 inches
Switch Contact Arrangement:
Single pole, double throw
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
Between 0.995 inches and 1.057 inches
Fragility Factor:
Moderately rugged
Boss Height:
Between 0.209 inches and 0.229 inches
Mounting Surface To Terminal End Distance:
Between 3.172 inches and 3.265 inches
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
4 threaded hole
Storage Type:
General purpose warehouse
Special Handling Feature:
Magnetic
Features Provided:
High inrush protection
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
15.0 amperes ac first location
Operating Voltage Type And Rating Per Pole In Volts:
24.0 dc second location
Operating Voltage Type And Rating Per Pole In Volts:
240.0 ac first location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
5000.0 ac first location
Circuit Protection Type:
Overcurrent first location
Circuit Protection Type:
Overvoltage second location
Trip Release Method:
Magnetic-hydraulic first location
Trip Release Characteristic:
Instantaneous second location
Trip Release Characteristic:
Time delay first location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 first location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
120.0 second location
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
2 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At each pole
External Actuator Linkage Arrangement:
One and two linked
Auxiliary Switch Function And Quantity:
1 alarm
Internal Trip Release Configuration:
Series trip first location
Internal Trip Release Configuration:
Relay trip second location
Thread Size:
0.138 inches
Switch Location And Position Designation:
External at pole one
Trip Delay Time In Seconds Per Rated Continuous Current:
15.000 at 200 pct first location and 70.000 at 200 pct first location
Inclosure Protection Type For Which Designed:
Dustproof
Switch Terminal Type:
Turret
Switch Current Rating And Type In Amps:
2.5 ac and 1.0 dc
Switch Voltage Rating And Type In Volts:
250.0 ac and 50.0 dc
Frequency In Hertz:
50.0 first location or 60.0 first location
Unpackaged Unit Weight:
11.000 ounces
Thread Series Designator:
Unc
Terminal Type And Quantity:
6 threaded stud
Item Name:
Breaker Assembly
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC