#26072 Individual Breaker | Circuit Breakers

26072

Circuit Breaker

NSN 5925-00-826-6901

DEMIL
Shelf Life
UOM
NIIN
Demil:
NO
Shelf Life:
N/A
UOM:
1 EA
NIIN:
008266901

Product Technical Spec.

Body Style:
Multipole-single actuator type
Body Length:
Between 5.240 inches and 5.260 inches
Body Width:
Between 2.990 inches and 3.010 inches
Body Height:
Between 2.677 inches and 2.697 inches
Case Material:
Plastic
Center To Center Distance Between Terminals Parallel To Length:
Between 4.349 inches and 4.369 inches
Center To Center Distance Between Terminals Parallel To Width:
Between 0.974 inches and 0.994 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 2.302 inches and 2.322 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
Between 0.974 inches and 0.994 inches
Fragility Factor:
Moderately rugged
Boss Height:
Between 0.209 inches and 0.229 inches
Pole Quantity:
3
Arc Quenching Method:
Air
Mounting Facility Type And Quantity:
4 threaded hole
Storage Type:
General purpose warehouse
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
15.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts:
250.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
5000.0 ac all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic all locations
Trip Release Characteristic:
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 all locations
Ultimate Trip Time Per Pole In Seconds:
10000.000 all locations
Reset Method:
Manual
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
1 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At pole two
Internal Trip Release Configuration:
Relay trip first location
Internal Trip Release Configuration:
Series trip second location
Internal Trip Release Configuration:
Series trip third location
Thread Size:
0.190 inches
Trip Delay Time In Seconds Per Rated Continuous Current:
70000.000 at 200 pct all locations and 20000.000 at 300 pct all locations
Inclosure Protection Type For Which Designed:
Fungus resistant and moisture resistant
Frequency In Hertz:
60.0 all locations
Thread Series Designator:
Unf
Terminal Type And Quantity:
6 threaded stud and 2 wire lead
NSN:
5925-00-826-6901
Item Name:
Breaker,individual
Cage Code:
28500

Cross Referenced Parts

Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC
Part Number:
62-467M6
Cage Code:
74193
RNCC:
5
RNVC:
1
RNAAC:
TX
Status:
A
MSDS:
SADC:
Cage Code:
74193
RNCC:
5
RNVC:
9
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
62-467M6
Cage Code:
74193
RNCC:
5
RNVC:
9
RNAAC:
TX
Status:
H
MSDS:
SADC:
Part Number:
62-467AMG4-15-250VAC-1-60H2-1REL
Cage Code:
74193
RNCC:
5
RNVC:
9
RNAAC:
TX
Status:
H
MSDS:
SADC:

  We Guarantee with Every Order

  •   100% Genuine Manufacturers Parts
  •   Every Product thoroughly Inspected
  •   Sales Record Retention of 7 years
  •   Fast Delivery
  •   HAZMAT Certified
  •   Global Shipping

Pricing & Availability

Submit this form for current pricing and availability quote on part number 26072 and/or cross reference parts.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:

We do not share or sell your information to anyone.
Privacy | Terms

Catalog Drilldown
--- Electrical And Electronic Equipment Components
------ Circuit Breakers
--------- Circuit Breakers
------------ P/N 26072

New Products Recently updated in circuit breakers

  • 27-10388-1 circuit breaker
    NSN 5925-00-166-3440

    Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height

  • 1536-007-10 circuit breaker
    NSN 5925-00-166-3440

    Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height

  • 314C920G21 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • KA3150 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • 504C336G21 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • BAB1015 circuit breaker
    NSN 5925-00-165-8694

    1 pole quantity, 15.0 amperes ac single location maximum continuous load current rating per pole, 240.0 ac single location operating voltage type and rating per pole in volts


Best-Selling Products A collection of our most popular products

Last Updated: 12/20/2024