#28923614 Tri-break Fused Circuit Breaker | Circuit Breakers

28923614

Circuit Breaker

NSN 5925-00-231-3660

DEMIL
Shelf Life
UOM
NIIN
Demil:
NO
Shelf Life:
N/A
UOM:
1 EA
NIIN:
002313660

Product Technical Spec.

Body Style:
Single pole type
Body Length:
Between 3.480 inches and 3.520 inches
Body Width:
Between 0.940 inches and 0.980 inches
Body Height:
Between 3.040 inches and 3.080 inches
Case Material:
Plastic
Switch Contact Arrangement:
Single pole, double throw
Fragility Factor:
Moderately rugged
Boss Height:
Between 0.178 inches and 0.198 inches
Pole Quantity:
1
Arc Quenching Method:
Air
Mounting Facility Type And Quantity:
2 terminal
Storage Type:
General purpose warehouse
Maximum Continuous Load Current Rating Per Pole:
20.0 amperes ac single location and 20.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts:
300.0 ac single location and 125.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
5000.0 ac single location and 2500.0 dc single location
Circuit Protection Type:
Overcurrent single location
Trip Release Method:
Thermal-magnetic single location
Trip Release Characteristic:
Instantaneous single location and time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
150.0 single location
Reset Method:
Manual
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
1 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At pole one
Auxiliary Switch Function And Quantity:
1 alarm
Switch Location And Position Designation:
External at pole one
Trip Delay Time In Seconds Per Rated Continuous Current:
10.000 at 200 pct single location and 210.000 at 200 pct single location
Inclosure Protection Type For Which Designed:
Dustproof
Trip Release Ambient Tempurature Rating:
50.0 degrees celsius single location
Switch Terminal Type:
Turret
Switch Current Rating And Type In Amps:
5.0 ac and 5.0 dc
Switch Voltage Rating And Type In Volts:
250.0 ac and 30.0 dc
Frequency In Hertz:
400.0 single location
Terminal Type And Quantity:
1 solder stud and 1 tab w/screw
NSN:
5925-00-231-3660
Item Name:
Tri-break Fused Circuit Breaker
Cage Code:
10001

Cross Referenced Parts

Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC
Part Number:
28992361-5
Cage Code:
10001
RNCC:
5
RNVC:
2
RNAAC:
9Z
Status:
A
MSDS:
SADC:
Part Number:
2601D45G04
Cage Code:
89946
RNCC:
5
RNVC:
2
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
565B159G16
Cage Code:
03497
RNCC:
5
RNVC:
9
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
2892361-4
Cage Code:
89946
RNCC:
5
RNVC:
9
RNAAC:
TX
Status:
A
MSDS:
SADC:

  We Guarantee with Every Order

  •   100% Genuine Manufacturers Parts
  •   Every Product thoroughly Inspected
  •   Sales Record Retention of 7 years
  •   Fast Delivery
  •   HAZMAT Certified
  •   Global Shipping

Pricing & Availability

Submit this form for current pricing and availability quote on part number 28923614 and/or cross reference parts.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:

We do not share or sell your information to anyone.
Privacy | Terms

Catalog Drilldown
--- Electrical And Electronic Equipment Components
------ Circuit Breakers
--------- Circuit Breakers
------------ P/N 28923614

New Products Recently updated in circuit breakers

  • 27-10388-1 circuit breaker
    NSN 5925-00-166-3440

    Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height

  • 1536-007-10 circuit breaker
    NSN 5925-00-166-3440

    Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height

  • 314C920G21 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • KA3150 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • 504C336G21 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • BAB1015 circuit breaker
    NSN 5925-00-165-8694

    1 pole quantity, 15.0 amperes ac single location maximum continuous load current rating per pole, 240.0 ac single location operating voltage type and rating per pole in volts


Best-Selling Products A collection of our most popular products

Last Updated: 04/26/2024