Product Features
No current on pole one
Detail Specifications
Body Style:
Multipole-single actuator type
Bushing Length:
Between 0.332 inches and 0.375 inches
Body Length:
1.500 inches
Center To Center Distance Between Terminals Parallel To Length:
Between 0.844 inches and 0.906 inches
Center To Center Distance Between Terminals Parallel To Width:
Between 0.595 inches and 0.656 inches
Nonturn Device Location:
At 3 oclock and at 9 oclock
Nonturn Device Diameter:
0.250 inches
Switch Contact Arrangement:
Single pole, double throw
Mounting Surface To Terminal End Distance:
1.780 inches
Mounting Facility Type And Quantity:
1 threaded bushing w/panel seal
Storage Type:
General purpose warehouse
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
20.0 amperes ac second location
Maximum Continuous Load Current Rating Per Pole:
20.0 amperes ac third location
Operating Voltage Type And Rating Per Pole In Volts:
115.0 ac first location
Operating Voltage Type And Rating Per Pole In Volts:
250.0 ac second location
Operating Voltage Type And Rating Per Pole In Volts:
250.0 ac third location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
300.0 ac third location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
300.0 ac second location
Circuit Protection Type:
Overvoltage first location
Trip Release Method:
Magnetic all locations
Trip Release Characteristic:
Instantaneous first location
Trip Release Characteristic:
Time delay second location
Trip Release Characteristic:
Time delay third location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
115.0 all locations
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
1 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At pole two
Auxiliary Switch Function And Quantity:
1 alarm
Internal Trip Release Configuration:
Relay trip first location
Internal Trip Release Configuration:
Series trip second location
Internal Trip Release Configuration:
Series trip third location
Thread Size:
0.375 inches
Switch Location And Position Designation:
Internal at pole three
Trip Delay Time In Seconds Per Rated Continuous Current:
0.500 at 200 pct second location and 9.000 at 200 pct second location
Trip Delay Time In Seconds Per Rated Continuous Current:
0.500 at 200 pct third location and 9.000 at 200 pct third location
Inclosure Protection Type For Which Designed:
Hermetically sealed and moisture resistant and salt spray proof and shockproof and vibrationproof
Switch Terminal Type:
Quick disconnect, male
Switch Current Rating And Type In Amps:
0.5 ac
Switch Voltage Rating And Type In Volts:
125.0 ac
Frequency In Hertz:
60.0 all locations
Thread Series Designator:
Unef
Terminal Type And Quantity:
6 wire hook and 2 quick disconnect, male
Item Name:
Breaker,individual
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC