#3018891 Motor Circuit Protector | Circuit Breakers

3018891

Circuit Breaker

NSN 5925-00-929-7717

DEMIL
Shelf Life
UOM
NIIN
Demil:
NO
Shelf Life:
N/A
UOM:
1 EA
NIIN:
009297717

Product Technical Spec.

Body Style:
Single pole type
Bushing Length:
0.359 inches
Body Length:
0.780 inches
Body Width:
0.580 inches
Case Material:
Metal
Center To Center Distance Between Terminals Parallel To Length:
0.593 inches
Fragility Factor:
Moderately rugged
Mounting Surface To Terminal End Distance:
1.420 inches
Pole Quantity:
1
Mounting Facility Type And Quantity:
1 threaded bushing w/panel seal
Storage Type:
General purpose warehouse
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
5.0 amperes ac single location and 5.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts:
200.0 ac single location and 28.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
800.0 ac single location and 800.0 dc single location
Circuit Protection Type:
Overcurrent single location
Trip Release Method:
Thermal single location
Trip Release Characteristic:
Time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
145.0 single location
Reset Method:
Manual
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
1 push-pull
Actuator Function:
Trip-reset
Actuator Position Designation:
At pole one
Internal Trip Release Configuration:
Series trip single location
Thread Size:
0.438 inches
Trip Delay Time In Seconds Per Rated Continuous Current:
2.000 at 200 pct single location and 20.000 at 200 pct single location
Inclosure Protection Type For Which Designed:
Explosion resistant and moisture resistant
Trip Release Ambient Tempurature Rating:
25.0 degrees celsius single location
Frequency In Hertz:
400.0 single location
Test Data Document:
81349-mil-c-5809 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
Thread Series Designator:
Un
Terminal Type And Quantity:
2 tab w/screw
Specification Data:
96906-ms26574 government standard
NSN:
5925-00-929-7717
Item Name:
Motor Circuit Protector
Cage Code:
00HHK

Cross Referenced Parts

Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC
Part Number:
4200-001-5
Cage Code:
81640
RNCC:
C
RNVC:
1
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
GX
Part Number:
GC885FD5
Cage Code:
26512
RNCC:
C
RNVC:
1
RNAAC:
TX
Status:
A
MSDS:
SADC:
AF
Part Number:
D7274-2-5
Cage Code:
82647
RNCC:
C
RNVC:
1
RNAAC:
TX
Status:
A
MSDS:
SADC:
AF
Part Number:
4200-001-5
Cage Code:
76374
RNCC:
C
RNVC:
1
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
GX
Part Number:
AS26574
Cage Code:
81343
RNCC:
3
RNVC:
1
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
AS58091
Cage Code:
81343
RNCC:
3
RNVC:
1
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
11040390-3
Cage Code:
18876
RNCC:
C
RNVC:
1
RNAAC:
TX
Status:
A
MSDS:
SADC:
AF
Part Number:
3600140-3
Cage Code:
07421
RNCC:
C
RNVC:
1
RNAAC:
TX
Status:
A
MSDS:
SADC:
AF
Part Number:
7274-2-5
Cage Code:
82647
RNCC:
C
RNVC:
1
RNAAC:
TX
Status:
A
MSDS:
SADC:
AF
Part Number:
7274-25-5
Cage Code:
82647
RNCC:
C
RNVC:
1
RNAAC:
TX
Status:
A
MSDS:
SADC:
AF
Part Number:
7274-26-5
Cage Code:
82647
RNCC:
C
RNVC:
1
RNAAC:
TX
Status:
A
MSDS:
SADC:
AF
Part Number:
7277-2-5
Cage Code:
82647
RNCC:
C
RNVC:
1
RNAAC:
TX
Status:
A
MSDS:
SADC:
AF
Part Number:
972.55.18.517
Cage Code:
S4080
RNCC:
5
RNVC:
2
RNAAC:
ZN
Status:
A
MSDS:
SADC:
Part Number:
235986
Cage Code:
H0212
RNCC:
5
RNVC:
2
RNAAC:
ZN
Status:
A
MSDS:
SADC:
Part Number:
MS26574-5
Cage Code:
81343
RNCC:
3
RNVC:
2
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
MIL-C-5809
Cage Code:
81349
RNCC:
5
RNVC:
9
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
MS26574-5
Cage Code:
96906
RNCC:
5
RNVC:
9
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
7277-2-5
Cage Code:
FA9C1
RNCC:
5
RNVC:
9
RNAAC:
ZF
Status:
A
MSDS:
SADC:
Part Number:
7S235986
Cage Code:
H0212
RNCC:
5
RNVC:
9
RNAAC:
ZN
Status:
A
MSDS:
SADC:

  We Guarantee with Every Order

  •   100% Genuine Manufacturers Parts
  •   Every Product thoroughly Inspected
  •   Sales Record Retention of 7 years
  •   Fast Delivery
  •   HAZMAT Certified
  •   Global Shipping

Pricing & Availability

Submit this form for current pricing and availability quote on part number 3018891 and/or cross reference parts.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:

We do not share or sell your information to anyone.
Privacy | Terms

Catalog Drilldown
--- Electrical And Electronic Equipment Components
------ Circuit Breakers
--------- Circuit Breakers
------------ P/N 3018891

New Products Recently updated in circuit breakers

  • 27-10388-1 circuit breaker
    NSN 5925-00-166-3440

    Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height

  • 1536-007-10 circuit breaker
    NSN 5925-00-166-3440

    Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height

  • 314C920G21 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • KA3150 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • 504C336G21 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • BAB1015 circuit breaker
    NSN 5925-00-165-8694

    1 pole quantity, 15.0 amperes ac single location maximum continuous load current rating per pole, 240.0 ac single location operating voltage type and rating per pole in volts


Best-Selling Products A collection of our most popular products

Last Updated: 11/14/2024