#313C748G23452D379G02452D377G07 Tri-break Fused Circuit Breaker | Circuit Breakers

313C748G23452D379G02452D377G07

Circuit Breaker

NSN 5925-01-153-0144

DEMIL
Shelf Life
UOM
NIIN
Demil:
NO
Shelf Life:
N/A
UOM:
EA
NIIN:
011530144

Product Features

Mounting hardware included

Detail Specifications

Body Style:
Multipole-single actuator type
Overall Height:
11.469 inches
Body Length:
12.000 inches
Body Width:
9.000 inches
Case Material:
Plastic
Switch Contact Arrangement:
Double pole, single throw, normally open
Fragility Factor:
Moderately rugged
Pole Quantity:
3
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
2 clip
Storage Type:
General purpose warehouse
Special Handling Feature:
Magnetic
Maximum Continuous Load Current Rating Per Pole:
175.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts:
500.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
1500.0 ac all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic all locations
Auxiliary Trip Coil Voltage Type And Rating In Volts:
120.0 dc all locations
Trip Release Characteristic:
Time delay all locations
Reset Method:
Manual
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
1 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At pole two
External Actuator Linkage Arrangement:
One, two, and three linked
Auxiliary Switch Function And Quantity:
1 control
Internal Trip Release Configuration:
Series trip w/remote trip feature all locations
Trip Release Duty Cycle:
Intermittent all locations
Switch Location And Position Designation:
Internal at pole one
Inclosure Protection Type For Which Designed:
Fungus resistant and moisture resistant
Switch Terminal Type:
Compression
Switch Current Rating And Type In Amps:
15.0 ac
Switch Voltage Rating And Type In Volts:
250.0 ac
Frequency In Hertz:
60.0 all locations
Unpackaged Unit Weight:
30.500 pounds
Terminal Type And Quantity:
6 threaded stud
NSN:
5925-01-153-0144
Item Name:
Tri-break Fused Circuit Breaker
Cage Code:
89946

Manufacturer Part Numbers

Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC
Part Number:
1279C57G12
Cage Code:
89946
RNCC:
5
RNVC:
1
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
45-819
Cage Code:
27192
RNCC:
3
RNVC:
2
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
ETN530610S36
Cage Code:
30086
RNCC:
5
RNVC:
2
RNAAC:
TX
Status:
A
MSDS:
SADC:

  We Guarantee with Every Order

  •   100% Genuine Manufacturers Parts
  •   Every Product thoroughly Inspected
  •   Sales Record Retention of 7 years
  •   Fast Delivery
  •   HAZMAT Certified
  •   Global Shipping

Pricing & Availability

Submit this form for current pricing and availability quote on part number 313c748g23452d379g02452d377g07 and/or cross reference parts.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:

We do not share or sell your information to anyone.
Privacy | Terms

Catalog Drilldown
--- Electrical And Electronic Equipment Components
------ Circuit Breakers
--------- Circuit Breakers
------------ P/N 313C748G23452D379G02452D377G07

New Products Recently updated in circuit breakers

  • 27-10388-1 circuit breaker
    NSN 5925-00-166-3440

    Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height

  • 1536-007-10 circuit breaker
    NSN 5925-00-166-3440

    Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height

  • 314C920G21 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • KA3150 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • 504C336G21 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • BAB1015 circuit breaker
    NSN 5925-00-165-8694

    1 pole quantity, 15.0 amperes ac single location maximum continuous load current rating per pole, 240.0 ac single location operating voltage type and rating per pole in volts


Best-Selling Products A collection of our most popular products

Last Updated: 04/16/2024