Detail Specifications
Body Style:
Multipole-multiple actuator type
Body Length:
Between 3.709 inches and
Body Width:
Between 3.042 inches and 3.062 inches
Center To Center Distance Between Terminals Parallel To Length:
Between 3.053 inches and 3.073 inches
Center To Center Distance Between Terminals Parallel To Width:
Between 1.021 inches and
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 2.740 inches and 2.760 inches
Switch Contact Arrangement:
Single pole, double throw
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
Between 1.021 inches and
Fragility Factor:
Moderately rugged
Boss Height:
Between 0.146 inches and 0.166 inches
Mounting Surface To Terminal End Distance:
3.239 inches
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
6 threaded hole
Storage Type:
General purpose warehouse
Special Handling Feature:
Magnetic
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
2000.0 milliamperes ac first location250.0 milliamperes ac second location1.0 amperes ac third location
Operating Voltage Type And Rating Per Pole In Volts:
208.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
1500.0 ac all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic all locations
Trip Release Characteristic:
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
150.0 all locations
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
3 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At each pole
External Actuator Linkage Arrangement:
One, two, and three linked
Auxiliary Switch Function And Quantity:
1 control
Internal Trip Release Configuration:
Series trip all locations
Thread Size:
0.138 inches
Switch Location And Position Designation:
External at pole three
Trip Delay Time In Seconds Per Rated Continuous Current:
2.000 at 200 pct all locations and
Trip Delay Time In Seconds Per Rated Continuous Current:
20.000 at 200 pct all locations
Inclosure Protection Type For Which Designed:
Fungus resistant and
Inclosure Protection Type For Which Designed:
Moisture resistant
Switch Terminal Type:
Tab, solder lug
Switch Current Rating And Type In Amps:
5.0 ac and 5.0 dc
Switch Voltage Rating And Type In Volts:
115.0 ac and 28.0 dc
Frequency In Hertz:
400.0 all locations
Thread Series Designator:
Unc
Terminal Type And Quantity:
6 threaded stud
Item Name:
Breaker,individual
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC
Part Number:
3XAM1516HEMG3-1A416VAC400C12