Technical Specifications of NSN
Body Style:
Multipole-multiple actuator type
Body Length:
Between 3.709 inches and
Body Width:
Between 3.042 inches and 3.062 inches
Center To Center Distance Between Terminals Parallel To Length:
Between 3.053 inches and 3.073 inches
Center To Center Distance Between Terminals Parallel To Width:
Between 1.021 inches and 1.041 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 2.740 inches and 2.760 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
Between 1.021 inches and 1.041 inches
Fragility Factor:
Moderately rugged
Boss Height:
Between 0.146 inches and 0.166 inches
Mounting Surface To Terminal End Distance:
3.239 inches
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
6 threaded hole
Storage Type:
General purpose warehouse
Special Handling Feature:
Magnetic
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
60.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts:
250.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
2000.0 ac all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic-hydraulic all locations
Trip Release Characteristic:
Instantaneous all locations and time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
150.0 all locations
Ultimate Trip Time Per Pole In Seconds:
0.800 all locations and 3.000 all locations
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
3 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At each pole
External Actuator Linkage Arrangement:
One, two, and three linked
Internal Trip Release Configuration:
Series trip first locationseries trip second locationrelay trip third location
Thread Size:
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current:
0.300 at 200 pct all locations and 1.000 at 200 pct all locations
Inclosure Protection Type For Which Designed:
Fungus resistant and general purpose and moisture resistant
Frequency In Hertz:
60.0 all locations
Test Data Document:
12436-a15136 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
Thread Series Designator:
Unc
Terminal Type And Quantity:
7 threaded stud
Item Name:
Thermal Magnetic Trip Breaker
Other Related Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC