#531604MG3 Breaker Assembly | Circuit Breakers

531604MG3

Circuit Breaker

NSN 5925-00-937-1586

DEMIL
Shelf Life
UOM
NIIN
Demil:
NO
Shelf Life:
UOM:
NIIN:
009371586

Detail Specifications

Body Style:
Multipole-multiple actuator type
Body Length:
Between 3.709 inches and 3.729 inches
Body Width:
Between 3.042 inches and 3.062 inches
Case Material:
Plastic
Center To Center Distance Between Terminals Parallel To Length:
Between 3.053 inches and 3.073 inches
Center To Center Distance Between Terminals Parallel To Width:
Between 1.021 inches and 1.041 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 2.740 inches and 2.760 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
Between 1.021 inches and 1.041 inches
Fragility Factor:
Moderately rugged
Boss Height:
Between 0.146 inches and 0.166 inches
Mounting Surface To Terminal End Distance:
3.329 inches
Pole Quantity:
3
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
6 threaded hole
Storage Type:
General purpose warehouse
Special Handling Feature:
Magnetic
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
30.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts:
250.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
1500.0 ac all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic-hydraulic all locations
Trip Release Characteristic:
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 all locations
Reset Method:
Manual
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
3 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At each pole
External Actuator Linkage Arrangement:
One, two, and three linked
Internal Trip Release Configuration:
Series trip all locations
Thread Size:
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current:
0.150 at 200 pct all locations and 1.500 at 200 pct all locations
Inclosure Protection Type For Which Designed:
Dustproof and fungus proof
Frequency In Hertz:
60.0 all locations
Thread Series Designator:
Unc
Terminal Type And Quantity:
6 threaded stud
NSN:
5925-00-937-1586
Item Name:
Breaker Assembly
Cage Code:
74193

Manufacturer Part Numbers

Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC
Part Number:
A15937-002
Cage Code:
12436
RNCC:
5
RNVC:
2
RNAAC:
SE
Status:
A
MSDS:
SADC:
Cage Code:
74193
RNCC:
3
RNVC:
9
RNAAC:
SB
Status:
A
MSDS:
SADC:
Part Number:
A15136-002
Cage Code:
12436
RNCC:
7
RNVC:
2
RNAAC:
SE
Status:
A
MSDS:
SADC:

  We Guarantee with Every Order

  •   100% Genuine Manufacturers Parts
  •   Every Product thoroughly Inspected
  •   Sales Record Retention of 7 years
  •   Fast Delivery
  •   HAZMAT Certified
  •   Global Shipping

Pricing & Availability

Submit this form for current pricing and availability quote on part number 531604mg3 and/or cross reference parts.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:

We do not share or sell your information to anyone.
Privacy | Terms

Catalog Drilldown
--- Electrical And Electronic Equipment Components
------ Circuit Breakers
--------- Circuit Breakers
------------ P/N 531604MG3

New Products Recently updated in circuit breakers

  • 27-10388-1 circuit breaker
    NSN 5925-00-166-3440

    Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height

  • 1536-007-10 circuit breaker
    NSN 5925-00-166-3440

    Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height

  • 314C920G21 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • KA3150 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • 504C336G21 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • BAB1015 circuit breaker
    NSN 5925-00-165-8694

    1 pole quantity, 15.0 amperes ac single location maximum continuous load current rating per pole, 240.0 ac single location operating voltage type and rating per pole in volts


Best-Selling Products A collection of our most popular products

Last Updated: 12/22/2024