#6TC210 Overload Switch | Circuit Breakers

6TC210

Circuit Breaker

NSN 5925-01-088-2837

DEMIL
Shelf Life
UOM
NIIN
Demil:
NO
Shelf Life:
N/A
UOM:
1 EA
NIIN:
010882837

Product Technical Spec.

Body Style:
Multipole-single actuator type
Bushing Length:
Between 0.219 inches and 0.281 inches
Body Length:
1.840 inches
Body Width:
Between 0.730 inches and 0.770 inches
Body Height:
Between 1.319 inches and 1.381 inches
Case Material:
Plastic
Center To Center Distance Between Terminals Parallel To Length:
Between 0.469 inches and 0.531 inches
Center To Center Distance Between Terminals Parallel To Width:
Between 0.593 inches and 0.655 inches
Pole Quantity:
3
Mounting Facility Type And Quantity:
Thd bushing
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
10.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts:
120.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
2000.0 ac all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Thermal all locations
Trip Release Characteristic:
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
145.0 all locations
Reset Method:
Manual
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
1 push-pull
Actuator Function:
Trip-reset
Actuator Position Designation:
At pole two
External Actuator Linkage Arrangement:
One, two, and three linked
Internal Trip Release Configuration:
Series trip all locations
Thread Size:
0.438 inches
Trip Delay Time In Seconds Per Rated Continuous Current:
4.000 at 200 pct all locations and 20.000 at 200 pct all locations and 0.400 at 500 pct all locations and 2.000 at 500 pct all locations and 0.100 at 1000 pct all locations and 0.530 at 1000 pct all locations
Trip Release Ambient Tempurature Rating:
25.0 degrees celsius all locations
Frequency In Hertz:
400.0 all locations
Thread Series Designator:
Uns
Terminal Type And Quantity:
6 screw
NSN:
5925-01-088-2837
Item Name:
Switch,overload
Cage Code:
82647

Cross Referenced Parts

Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC
Part Number:
6TC2-10B
Cage Code:
82647
RNCC:
3
RNVC:
2
RNAAC:
9Z
Status:
A
MSDS:
SADC:
Part Number:
6TC2-10
Cage Code:
F2210
RNCC:
5
RNVC:
2
RNAAC:
ZF
Status:
A
MSDS:
SADC:

  We Guarantee with Every Order

  •   100% Genuine Manufacturers Parts
  •   Every Product thoroughly Inspected
  •   Sales Record Retention of 7 years
  •   Fast Delivery
  •   HAZMAT Certified
  •   Global Shipping

Pricing & Availability

Submit this form for current pricing and availability quote on part number 6tc210 and/or cross reference parts.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:

We do not share or sell your information to anyone.
Privacy | Terms

Catalog Drilldown
--- Electrical And Electronic Equipment Components
------ Circuit Breakers
--------- Circuit Breakers
------------ P/N 6TC210

New Products Recently updated in circuit breakers

  • 27-10388-1 circuit breaker
    NSN 5925-00-166-3440

    Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height

  • 1536-007-10 circuit breaker
    NSN 5925-00-166-3440

    Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height

  • 314C920G21 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • KA3150 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • 504C336G21 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • BAB1015 circuit breaker
    NSN 5925-00-165-8694

    1 pole quantity, 15.0 amperes ac single location maximum continuous load current rating per pole, 240.0 ac single location operating voltage type and rating per pole in volts


Best-Selling Products A collection of our most popular products

Last Updated: 04/23/2024