Detail Specifications

Body Style:
Multipole-single actuator type
Bushing Length:
0.380 inches
Body Length:
1.500 inches
Body Width:
1.875 inches
Case Material:
Metal
Center To Center Distance Between Terminals Parallel To Length:
0.875 inches
Center To Center Distance Between Terminals Parallel To Width:
0.625 inches
Nonturn Device Location:
At 3 oclock and at 9 oclock
Nonturn Device Radius:
0.625 inches
Nonturn Device Length:
0.130 inches
Nonturn Device Diameter:
0.140 inches
Fragility Factor:
Moderately rugged
Mounting Surface To Terminal End Distance:
1.780 inches
Pole Quantity:
3
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
1 threaded bushing w/panel seal
Storage Type:
General purpose warehouse
Special Handling Feature:
Magnetic
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
10.0 amperes ac second location
Maximum Continuous Load Current Rating Per Pole:
15.0 amperes ac third location
Maximum Continuous Load Current Rating Per Pole:
5.0 amperes ac first location
Operating Voltage Type And Rating Per Pole In Volts:
240.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
1000.0 ac all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic all locations
Trip Release Characteristic:
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 all locations
Reset Method:
Manual
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
1 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At pole two
Internal Trip Release Configuration:
Series trip all locations
Thread Size:
0.375 inches
Trip Delay Time In Seconds Per Rated Continuous Current:
0.055 at 200 pct second location and 0.950 at 200 pct second location
Trip Delay Time In Seconds Per Rated Continuous Current:
0.055 at 200 pct third location and 0.950 at 200 pct third location
Trip Delay Time In Seconds Per Rated Continuous Current:
0.500 at 200 pct first location and 9.000 at 200 pct first location
Inclosure Protection Type For Which Designed:
Hermetically sealed
Frequency In Hertz:
400.0 all locations
Thread Series Designator:
Unef
Terminal Type And Quantity:
6 wire hook
NSN:
5925-01-219-1817
Item Name:
Line Protective Switch
Cage Code:
16236

Manufacturer Part Numbers

Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC
Part Number:
AP-112-1036-2
Cage Code:
81541
RNCC:
3
RNVC:
2
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
71010009002
Cage Code:
89944
RNCC:
5
RNVC:
2
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
71010009002
Cage Code:
98750
RNCC:
5
RNVC:
9
RNAAC:
TX
Status:
A
MSDS:
SADC:

  We Guarantee with Every Order

  •   100% Genuine Manufacturers Parts
  •   Every Product thoroughly Inspected
  •   Sales Record Retention of 7 years
  •   Fast Delivery
  •   HAZMAT Certified
  •   Global Shipping

Pricing & Availability

Submit this form for current pricing and availability quote on part number 7101000900298750 and/or cross reference parts.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:

We do not share or sell your information to anyone.
Privacy | Terms

Catalog Drilldown
--- Electrical And Electronic Equipment Components
------ Circuit Breakers
--------- Circuit Breakers
------------ P/N 7101000900298750

New Products Recently updated in circuit breakers

  • 27-10388-1 circuit breaker
    NSN 5925-00-166-3440

    Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height

  • 1536-007-10 circuit breaker
    NSN 5925-00-166-3440

    Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height

  • 314C920G21 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • KA3150 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • 504C336G21 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • BAB1015 circuit breaker
    NSN 5925-00-165-8694

    1 pole quantity, 15.0 amperes ac single location maximum continuous load current rating per pole, 240.0 ac single location operating voltage type and rating per pole in volts


Best-Selling Products A collection of our most popular products

Last Updated: 11/25/2024