Detail Specifications
Thread Pitch Diameters:
+0.1177/+0.1214 inches
Body Style:
Multipole-multiple actuator type
Body Length:
Between 2.480 inches and 2.500 inches
Center To Center Distance Between Terminals Parallel To Length:
Between 1.925 inches and 1.955 inches
Center To Center Distance Between Terminals Parallel To Width:
Between 0.735 inches and 0.765 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 2.050 inches and 2.070 inches
Switch Contact Arrangement:
Single pole, double throw
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
Between 0.735 inches and 0.765 inches
Fragility Factor:
Moderately rugged
Boss Height:
Between 0.135 inches and 0.165 inches
Mounting Surface To Terminal End Distance:
2.625 inches
Mounting Facility Type And Quantity:
12 threaded hole
Storage Type:
General purpose warehouse
Special Handling Feature:
Magnetic
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
15.0 amperes ac third location
Maximum Continuous Load Current Rating Per Pole:
15.0 amperes ac first location
Maximum Continuous Load Current Rating Per Pole:
15.0 amperes ac second location
Maximum Continuous Load Current Rating Per Pole:
7.0 amperes ac fifth location
Maximum Continuous Load Current Rating Per Pole:
7.0 amperes ac fourth location
Maximum Continuous Load Current Rating Per Pole:
7.0 amperes ac sixth location
Operating Voltage Type And Rating Per Pole In Volts:
250.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
1000.0 ac all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic all locations
Trip Release Characteristic:
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
115.0 all locations
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
6 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At each pole
External Actuator Linkage Arrangement:
One, two, three, four, five, and six linked
Auxiliary Switch Function And Quantity:
1 alarm
Internal Trip Release Configuration:
Series trip all locations
Thread Size:
0.138 inches
Switch Location And Position Designation:
Internal at pole four and internal at pole five and internal at pole six
Trip Delay Time In Seconds Per Rated Continuous Current:
2.000 at 200 pct all locations and 22.000 at 200 pct all locations
Inclosure Protection Type For Which Designed:
Corrosion resistant and moisture resistant and shockproof and vibrationproof
Switch Terminal Type:
Pin
Switch Current Rating And Type In Amps:
10.0 ac
Switch Voltage Rating And Type In Volts:
120.0 ac
Frequency In Hertz:
400.0 all locations
Unpackaged Unit Weight:
22.200 ounces
Thread Series Designator:
Unc
Terminal Type And Quantity:
12 threaded stud
Item Name:
Breaker,individual
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC