Detail Specifications
Body Style:
Single pole type
Bushing Length:
Between 0.313 inches and 0.375 inches
Body Length:
2.187 inches
Center To Center Distance Between Terminals Parallel To Length:
Between 0.875 inches and 0.937 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 1.802 inches and 1.822 inches
Nonturn Device Location:
At 12 oclock
Nonturn Device Length:
0.045 inches
Nonturn Device Diameter:
0.100 inches
Fragility Factor:
Moderately rugged
Mounting Surface To Terminal End Distance:
1.343 inches
Mounting Facility Type And Quantity:
2 threaded hole
Storage Type:
General purpose warehouse
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
5.0 amperes ac single location and 5.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts:
115.0 ac single location and 28.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
3500.0 ac single location and 3500.0 dc single location
Circuit Protection Type:
Overcurrent single location
Trip Release Method:
Thermal single location
Trip Release Characteristic:
Time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
138.0 single location
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
1 push-pull
Actuator Function:
Trip-reset
Actuator Position Designation:
At pole one
Internal Trip Release Configuration:
Series trip single location
Thread Size:
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current:
40.000 at 200 pct single location and 100.000 at 200 pct single location
Inclosure Protection Type For Which Designed:
Corrosion resistant and dusttight and moisture resistant and sand resistant and explosion proof and shockproof and vibration resistant
Trip Release Ambient Tempurature Rating:
25.0 degrees celsius single location
Frequency In Hertz:
400.0 single location
Unpackaged Unit Weight:
0.078 pounds
Precious Material:
Silver
Test Data Document:
81349-mil-c-5809 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
Thread Series Designator:
Unc
Terminal Type And Quantity:
2 tab w/screw
Specification Data:
96906-ms24510 government standard
Item Name:
Breaker,circuit
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC