Technical Specifications of NSN
Body Style:
Multipole-multiple actuator type
Body Length:
Between 2.485 inches and 2.515 inches
Body Width:
Between 2.230 inches and 2.270 inches
Center To Center Distance Between Terminals Parallel To Length:
Between 1.925 inches and 1.955 inches
Center To Center Distance Between Terminals Parallel To Width:
Between 0.735 inches and 0.765 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 2.047 inches and 2.077 inches
Switch Contact Arrangement:
Single pole, double throw
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
Between 0.735 inches and 0.765 inches
Fragility Factor:
Moderately rugged
Boss Height:
Between 0.125 inches and 0.155 inches
Mounting Surface To Terminal End Distance:
Between 2.650 inches and 2.800 inches
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
6 threaded hole
Storage Type:
General purpose warehouse
Special Handling Feature:
Magnetic
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
3.0 amperes ac all locations and 3.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts:
250.0 ac all locations and 50.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
1000.0 ac all locations and 2000.0 dc all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic all locations
Trip Release Characteristic:
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
150.0 all locations
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
3 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At each pole
External Actuator Linkage Arrangement:
One, two, and three linked
Auxiliary Switch Function And Quantity:
1 alarm
Internal Trip Release Configuration:
Series trip all locations
Thread Size:
0.138 inches
Switch Location And Position Designation:
Internal at each pole
Trip Delay Time In Seconds Per Rated Continuous Current:
3.000 at 200 pct all locations and 10.000 at 200 pct all locations
Inclosure Protection Type For Which Designed:
Shock resistant and vibration resistant and moisture resistant and salt spray proof
Switch Terminal Type:
Tab, solder lug
Switch Current Rating And Type In Amps:
5.0 ac and 1.0 dc
Switch Voltage Rating And Type In Volts:
115.0 ac and 50.0 dc
Frequency In Hertz:
400.0 all locations
Unpackaged Unit Weight:
0.875 pounds
Test Data Document:
05869-711570 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
Thread Series Designator:
Unc
Terminal Type And Quantity:
6 threaded stud
Item Name:
Tri-break Fused Circuit Breaker
Other Related Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC