Detail Specifications
Body Style:
Multipole-multiple actuator type
Body Length:
2.530 inches
Center To Center Distance Between Terminals Parallel To Length:
1.940 inches
Center To Center Distance Between Terminals Parallel To Width:
Between 0.750 inches and 0.770 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 2.050 inches and 2.070 inches
Switch Contact Arrangement:
Single pole, double throw
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
Between 0.750 inches and 0.770 inches
Fragility Factor:
Moderately rugged
Boss Height:
0.150 inches
Mounting Surface To Terminal End Distance:
2.522 inches
Mounting Facility Type And Quantity:
8 threaded hole
Storage Type:
General purpose warehouse
Special Handling Feature:
Magnetic
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
15.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts:
250.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
1500.0 ac all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic-hydraulic all locations
Trip Release Characteristic:
Instantaneous fourth location
Trip Release Characteristic:
Time delay second location
Trip Release Characteristic:
Time delay third location
Trip Release Characteristic:
Time delay first location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
150.0 all locations
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
4 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At each pole
External Actuator Linkage Arrangement:
One, two, three, and four linked
Auxiliary Switch Function And Quantity:
1 alarm
Internal Trip Release Configuration:
Relay trip fourth location
Internal Trip Release Configuration:
Series trip first location
Internal Trip Release Configuration:
Series trip second location
Internal Trip Release Configuration:
Series trip third location
Thread Size:
0.138 inches
Switch Location And Position Designation:
Internal at pole three
Trip Delay Time In Seconds Per Rated Continuous Current:
0.600 at 200 pct first location and 5.000 at 200 pct first location
Trip Delay Time In Seconds Per Rated Continuous Current:
0.600 at 200 pct second location and 5.000 at 200 pct second location
Trip Delay Time In Seconds Per Rated Continuous Current:
0.600 at 200 pct third location and 5.000 at 200 pct third location
Inclosure Protection Type For Which Designed:
Moisture resistant and fungus resistant and vibration resistant and shock resistant and explosion proof
Switch Terminal Type:
Tab, solder lug
Switch Current Rating And Type In Amps:
5.0 ac and 1.0 dc
Switch Voltage Rating And Type In Volts:
125.0 ac and 50.0 dc
Frequency In Hertz:
400.0 all locations
Thread Series Designator:
Unc
Terminal Type And Quantity:
10 threaded stud
Specification Data:
12436-a15912 government specification
Item Name:
Thermal Magnetic Trip Breaker
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC