Technical Specifications of NSN
Body Style:
Multipole-multiple actuator type
Body Length:
2.000 inches
Center To Center Distance Between Terminals Parallel To Length:
1.560 inches
Center To Center Distance Between Terminals Parallel To Width:
0.750 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
1.660 inches
Switch Contact Arrangement:
Single pole, double throw
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
0.750 inches
Boss Height:
0.130 inches
Mounting Surface To Terminal End Distance:
2.032 inches
Mounting Facility Type And Quantity:
8 threaded hole
Storage Type:
General purpose warehouse
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
15.0 amperes ac fourth location and 15.0 amperes dc fourth location
Maximum Continuous Load Current Rating Per Pole:
4.0 amperes ac first location
Maximum Continuous Load Current Rating Per Pole:
4.0 amperes ac second location
Maximum Continuous Load Current Rating Per Pole:
4.0 amperes ac third location
Operating Voltage Type And Rating Per Pole In Volts:
240.0 ac fourth location and 65.0 dc fourth location
Operating Voltage Type And Rating Per Pole In Volts:
240.0 ac second location
Operating Voltage Type And Rating Per Pole In Volts:
240.0 ac first location
Operating Voltage Type And Rating Per Pole In Volts:
240.0 ac third location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
1000.0 ac first location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
1000.0 ac fourth location and 1000.0 dc fourth location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
1000.0 ac second location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
1000.0 ac third location
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic all locations
Trip Release Characteristic:
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
150.0 all locations
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
4 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At each pole
External Actuator Linkage Arrangement:
One, two, three, and four linked
Auxiliary Switch Function And Quantity:
1 alarm
Internal Trip Release Configuration:
Series trip first location
Internal Trip Release Configuration:
Relay trip fourth location
Internal Trip Release Configuration:
Series trip second location
Internal Trip Release Configuration:
Series trip third location
Thread Size:
0.138 inches
Switch Location And Position Designation:
Internal at pole one
Trip Delay Time In Seconds Per Rated Continuous Current:
0.150 at 200 pct all locations and 1.900 at 200 pct all locations
Inclosure Protection Type For Which Designed:
Moisture resistant and shock resistant and vibration resistant
Switch Terminal Type:
Tab, solder lug
Switch Current Rating And Type In Amps:
5.0 ac and 5.0 dc
Switch Voltage Rating And Type In Volts:
240.0 ac and 50.0 dc
Frequency In Hertz:
400.0 all locations
Test Data Document:
18323-7489a63 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
Thread Series Designator:
Unc
Terminal Type And Quantity:
10 tab w/screw
Item Name:
Breaker,circuit
Other Related Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC