Detail Specifications
Body Style:
Multipole-multiple actuator type
Body Length:
Between 2.480 inches and 2.500 inches
Center To Center Distance Between Terminals Parallel To Length:
Between 1.925 inches and 1.955 inches
Center To Center Distance Between Terminals Parallel To Width:
Between 0.735 inches and 0.765 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 2.050 inches and 2.070 inches
Switch Contact Arrangement:
Single pole, double throw
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
Between 0.735 inches and 0.765 inches
Fragility Factor:
Moderately rugged
Boss Height:
Between 0.135 inches and 0.165 inches
Mounting Surface To Terminal End Distance:
2.491 inches
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
6 threaded hole
Storage Type:
General purpose warehouse
Special Handling Feature:
Magnetic
Maximum Continuous Load Current Rating Per Pole:
1.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts:
277.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
5000.0 ac all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic all locations
Trip Release Characteristic:
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
115.0 all locations
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
3 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At each pole
External Actuator Linkage Arrangement:
One, two, and three linked
Auxiliary Switch Function And Quantity:
1 alarm
Internal Trip Release Configuration:
Series trip all locations
Thread Size:
3.0 millimeters
Thread Pitch In Millimeters:
0.50
Switch Location And Position Designation:
Internal at pole one
Trip Delay Time In Seconds Per Rated Continuous Current:
2.000 at 200 pct all locations and 22.000 at 200 pct all locations
Inclosure Protection Type For Which Designed:
Fungus resistant and
Inclosure Protection Type For Which Designed:
Moisture resistant and shock resistant and
Inclosure Protection Type For Which Designed:
Salt spray proof and
Inclosure Protection Type For Which Designed:
Vibration resistant
Switch Terminal Type:
Quick disconnect, male
Switch Current Rating And Type In Amps:
10.0 ac and 3.0 dc
Switch Voltage Rating And Type In Volts:
250.0 ac and 50.0 dc
Frequency In Hertz:
50.0 all locations or 60.0 all locations
Unpackaged Unit Weight:
11.100 ounces
Thread Series Designator:
Iso s
Terminal Type And Quantity:
6 threaded stud
Item Name:
Breaker,input Mains
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC