#940-003-100 Overload Switch | Circuit Breakers

940-003-100

Circuit Breaker

NSN 5925-00-883-3843

DEMIL
Shelf Life
UOM
NIIN
Demil:
NO
Shelf Life:
N/A
UOM:
1 EA
NIIN:
008833843

Technical Specifications of NSN

Body Length:
2.631 inches
Body Width:
2.187 inches
Case Material:
Plastic
Center To Center Distance Between Terminals Parallel To Length:
Between 1.422 inches and 1.452 inches
Center To Center Distance Between Terminals Parallel To Width:
Between 0.860 inches and 0.890 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 1.797 inches and 1.827 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
Between 0.860 inches and 0.890 inches
Fragility Factor:
Moderately rugged
Mounting Surface To Terminal End Distance:
Between 2.422 inches and 2.452 inches
Pole Quantity:
3
Arc Quenching Method:
Air
Mounting Facility Type And Quantity:
6 threaded hole
Storage Type:
General purpose warehouse
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
100.0 amperes ac all locations and 100.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts:
115.0 ac all locations and 30.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
2500.0 ac all locations and 6000.0 dc all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Thermal all locations
Trip Release Characteristic:
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
138.0 all locations
Reset Method:
Manual
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
3 push-pull
Actuator Function:
Trip-reset
Actuator Position Designation:
At each pole
External Actuator Linkage Arrangement:
One, two, and three linked
Internal Trip Release Configuration:
Series trip all locations
Thread Size:
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current:
15.000 at 200 pct all locations and 55.000 at 200 pct all locations
Inclosure Protection Type For Which Designed:
General purpose
Trip Release Ambient Tempurature Rating:
25.0 degrees celsius all locations
Frequency In Hertz:
400.0 all locations
Unpackaged Unit Weight:
0.625 pounds
Precious Material And Location:
Contact surfaces silver
Precious Material:
Silver
Thread Series Designator:
Unc
Terminal Type And Quantity:
6 tab w/screw
NSN:
5925-00-883-3843
Item Name:
Overload Switch
Cage Code:
76374

Other Related Parts

Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC
Part Number:
10607304-5
Cage Code:
19204
RNCC:
5
RNVC:
2
RNAAC:
BF
Status:
A
MSDS:
SADC:
Part Number:
10607304-5
Cage Code:
38597
RNCC:
5
RNVC:
2
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
10607304-5
Cage Code:
18876
RNCC:
3
RNVC:
2
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
10607304-5
Cage Code:
04939
RNCC:
5
RNVC:
9
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
940-003-100
Cage Code:
81640
RNCC:
5
RNVC:
2
RNAAC:
ZZ
Status:
A
MSDS:
SADC:

  We Guarantee with Every Order

  •   100% Genuine Manufacturers Parts
  •   Every Product thoroughly Inspected
  •   Sales Record Retention of 7 years
  •   Fast Delivery
  •   HAZMAT Certified
  •   Global Shipping

Pricing & Availability

Submit this form for current pricing and availability quote on part number 940-003-100 and/or cross reference parts.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:

We do not share or sell your information to anyone.
Privacy | Terms

Catalog Drilldown
--- Electrical And Electronic Equipment Components
------ Circuit Breakers
--------- Circuit Breakers
------------ P/N 940-003-100

New Products Recently updated in circuit breakers

  • 27-10388-1 circuit breaker
    NSN 5925-00-166-3440

    Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height

  • 1536-007-10 circuit breaker
    NSN 5925-00-166-3440

    Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height

  • 314C920G21 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • KA3150 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • 504C336G21 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • BAB1015 circuit breaker
    NSN 5925-00-165-8694

    1 pole quantity, 15.0 amperes ac single location maximum continuous load current rating per pole, 240.0 ac single location operating voltage type and rating per pole in volts


Best-Selling Products A collection of our most popular products

Last Updated: 11/27/2024