Technical Specifications of NSN
Body Style:
Multipole-multiple actuator type
Body Length:
3.015 inches
Center To Center Distance Between Terminals Parallel To Length:
1.940 inches
Center To Center Distance Between Terminals Parallel To Width:
0.750 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
2.250 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
0.750 inches
End Application:
5895-01-467-7213
Boss Height:
1.042 inches
Mounting Surface To Terminal End Distance:
2.529 inches
Mounting Facility Type And Quantity:
6 threaded stud
Maximum Continuous Load Current Rating Per Pole:
120.0 milliamperes dc fourth location
Maximum Continuous Load Current Rating Per Pole:
20.0 amperes ac second location
Maximum Continuous Load Current Rating Per Pole:
20.0 amperes ac third location
Maximum Continuous Load Current Rating Per Pole:
20.0 amperes ac first location
Operating Voltage Type And Rating Per Pole In Volts:
250.0 ac second location
Operating Voltage Type And Rating Per Pole In Volts:
250.0 ac first location
Operating Voltage Type And Rating Per Pole In Volts:
250.0 ac third location
Operating Voltage Type And Rating Per Pole In Volts:
28.0 dc fourth location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
1000.0 ac all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Thermal-magnetic all locations
Trip Release Characteristic:
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 all locations
Main Contact Tripping Mechanism Type:
Trip free
Thread Size:
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current:
0.000 at 125 pct fourth location
Trip Delay Time In Seconds Per Rated Continuous Current:
63.000 at 125 pct first location
Trip Delay Time In Seconds Per Rated Continuous Current:
63.000 at 125 pct second location
Trip Delay Time In Seconds Per Rated Continuous Current:
63.000 at 125 pct third location
Trip Release Ambient Tempurature Rating:
70.0 degrees celsius all locations
Frequency In Hertz:
60.0 all locations
Thread Series Designator:
Unc
Terminal Type And Quantity:
6 threaded stud
Item Name:
Tri-break Fused Circuit Breaker
Other Related Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC
Part Number:
IULHK1119-30372-20
Part Number:
99002A8046-20
Part Number:
IULHK1119-30372-20
Part Number:
99002A8046-20
Part Number:
IULHK1119-30372-20
Part Number:
99002A8046-20
Part Number:
IULHK1119-30372-20
Part Number:
99002A8046-20
Part Number:
IULHK1119-30372-20
Part Number:
99002A8046-20