Product Features
Pole one is switch only
Description
Multipole-multiple actuator type body style, 2.490 inches body length, 2.960 inches body width, plastic case material, 1.928 inches center to center distance between terminals parallel to length.
Detail Specifications
Body Style:
Multipole-multiple actuator type
Body Length:
Between 2.490 inches and 2.510 inches
Body Width:
Between 2.960 inches and 3.040 inches
Center To Center Distance Between Terminals Parallel To Length:
Between 1.928 inches and 1.948 inches
Center To Center Distance Between Terminals Parallel To Width:
Between 0.740 inches and 0.760 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 2.052 inches and 2.072 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
Between 0.740 inches and 0.760 inches
Fragility Factor:
Moderately rugged
Boss Height:
Between 0.130 inches and 0.150 inches
Mounting Surface To Terminal End Distance:
Between 2.539 inches and 2.683 inches
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
8 threaded hole
Storage Type:
General purpose warehouse
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
25.0 amperes ac fourth location
Maximum Continuous Load Current Rating Per Pole:
25.0 amperes ac second location
Maximum Continuous Load Current Rating Per Pole:
25.0 amperes ac third location
Maximum Continuous Load Current Rating Per Pole:
50.0 amperes ac first location
Operating Voltage Type And Rating Per Pole In Volts:
208.0 ac fourth location
Operating Voltage Type And Rating Per Pole In Volts:
208.0 ac second location
Operating Voltage Type And Rating Per Pole In Volts:
208.0 ac third location
Operating Voltage Type And Rating Per Pole In Volts:
250.0 ac first location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
1000.0 ac fourth location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
1000.0 ac second location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
1000.0 ac third location
Circuit Protection Type:
Overcurrent fourth location
Circuit Protection Type:
Overcurrent second location
Circuit Protection Type:
Overcurrent third location
Trip Release Method:
Magnetic-hydraulic fourth location
Trip Release Method:
Magnetic-hydraulic second location
Trip Release Method:
Magnetic-hydraulic third location
Trip Release Characteristic:
Time delay fourth location
Trip Release Characteristic:
Time delay second location
Trip Release Characteristic:
Time delay third location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 fourth location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 second location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 third location
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
4 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At each pole
External Actuator Linkage Arrangement:
One, two, three, and four linked
Internal Trip Release Configuration:
Relay trip fourth location
Internal Trip Release Configuration:
Relay trip second location
Internal Trip Release Configuration:
Relay trip third location
Thread Size:
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current:
4.100 at 200 pct fourth location and 14.000 at 200 pct fourth location
Trip Delay Time In Seconds Per Rated Continuous Current:
4.100 at 200 pct second location and 14.000 at 200 pct second location
Trip Delay Time In Seconds Per Rated Continuous Current:
4.100 at 200 pct third location and 14.000 at 200 pct third location
Inclosure Protection Type For Which Designed:
Fungus resistant and humidity resistant and moisture resistant and shock resistant and vibration resistant
Frequency In Hertz:
60.0 all locations
Unpackaged Unit Weight:
13.000 ounces
Thread Series Designator:
Unc
Terminal Type And Quantity:
8 threaded stud
Item Name:
Breaker Assembly
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC