Product Features
Temp range m40.0 to 185.0 fah. Tested iaw mil-std-202 methods 101, 106, 103 cond a, 213 cond i, 204, 301, 302.
Product Technical Spec.
Body Style:
Multipole-multiple actuator type
Body Length:
Between 2.469 inches and 2.531 inches
Body Width:
Between 1.469 inches and 1.531 inches
Center To Center Distance Between Terminals Parallel To Length:
Between 1.909 inches and 1.971 inches
Center To Center Distance Between Terminals Parallel To Width:
Between 0.719 inches and 0.781 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 2.031 inches and 2.093 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
Between 0.719 inches and 0.781 inches
End Application:
Missle, minuteman lgm-30, test set
Boss Height:
Between 0.109 inches and 0.171 inches
Mounting Surface To Terminal End Distance:
Between 1.829 inches and 1.891 inches
Mounting Facility Type And Quantity:
4 threaded hole
Features Provided:
High inrush protection
Maximum Continuous Load Current Rating Per Pole:
20.0 amperes ac all locations and 20.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts:
240.0 ac all locations and 80.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
5000.0 ac all locations and 5000.0 dc all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic-hydraulic all locations
Trip Release Characteristic:
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
135.0 all locations
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
2 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At each pole
External Actuator Linkage Arrangement:
One and two linked
Internal Trip Release Configuration:
Series trip all locations
Thread Size:
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current:
1.700 at 200 pct all locations and 18.000 at 200 pct all locations
Part Name Assigned By Controlling Agency:
Circuit breaker
Frequency In Hertz:
50.0 all locations or 60.0 all locations
Test Data Document:
Mil-c-55629 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.). And mil-std-202 standard (includes industry or association standards, individual manufactureer standards, etc.).
Thread Series Designator:
Unc
Terminal Type And Quantity:
4 threaded stud
Item Name:
Switch,overload
Cross Referenced Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS