Product Technical Spec.
Body Style:
Multipole-multiple actuator type
Body Length:
2.500 inches
Body Width:
Between 2.200 inches and 2.800 inches
Center To Center Distance Between Terminals Parallel To Length:
1.938 inches
Center To Center Distance Between Terminals Parallel To Width:
0.750 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
2.062 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
0.750 inches
Fragility Factor:
Moderately rugged
Boss Height:
0.140 inches
Mounting Surface To Terminal End Distance:
Between 2.409 inches and 2.533 inches
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
6 threaded hole
Storage Type:
General purpose warehouse
Special Handling Feature:
Magnetic
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
20.0 amperes ac second location
Maximum Continuous Load Current Rating Per Pole:
20.0 amperes ac first location
Maximum Continuous Load Current Rating Per Pole:
3.0 amperes dc third location
Operating Voltage Type And Rating Per Pole In Volts:
102.0 dc third location
Operating Voltage Type And Rating Per Pole In Volts:
115.0 ac second location
Operating Voltage Type And Rating Per Pole In Volts:
250.0 ac first location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
1000.0 ac first location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
1000.0 ac second location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
1000.0 dc third location
Circuit Protection Type:
Overcurrent first location
Circuit Protection Type:
Overcurrent second location
Circuit Protection Type:
Undervoltage third location
Trip Release Method:
Magnetic-hydraulic all locations
Auxiliary Trip Coil Voltage Type And Rating In Volts:
120.0 ac first location
Trip Release Characteristic:
Instantaneous second location
Trip Release Characteristic:
Instantaneous third location
Trip Release Characteristic:
Time delay first location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 all locations
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
3 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At each pole
External Actuator Linkage Arrangement:
One, two, and three linked
Internal Trip Release Configuration:
Relay trip second location
Internal Trip Release Configuration:
Relay trip third location
Internal Trip Release Configuration:
Series/relay trip first location
Thread Size:
0.138 inches
Trip Release Duty Cycle:
Intermittent first location
Trip Delay Time In Seconds Per Rated Continuous Current:
2.000 at 200 pct first location and 20.000 at 200 pct first location
Inclosure Protection Type For Which Designed:
Fungus resistant and moisture resistant
Frequency In Hertz:
50.0 first location or 60.0 first location
Frequency In Hertz:
50.0 second location or 60.0 second location
Unpackaged Unit Weight:
9.500 ounces
Thread Series Designator:
Unc
Terminal Type And Quantity:
6 threaded stud
Item Name:
Breaker,circuit
Cross Referenced Parts
No other part numbers with same form, fit, and function found.