Detail Specifications
Body Style:
Multipole-multiple actuator type
Body Length:
Between 2.480 inches and 2.500 inches
Body Width:
Between 2.990 inches and 3.010 inches
Center To Center Distance Between Terminals Parallel To Length:
Between 1.925 inches and 1.955 inches
Center To Center Distance Between Terminals Parallel To Width:
Between 0.715 inches and 0.745 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 2.050 inches and 2.070 inches
Switch Contact Arrangement:
Single pole, double throw
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
Between 0.715 inches and 0.745 inches
Fragility Factor:
Moderately rugged
Boss Height:
0.165 inches
Mounting Surface To Terminal End Distance:
1.835 inches
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
8 threaded hole
Storage Type:
General purpose warehouse
Special Handling Feature:
Magnetic
Features Provided:
High inrush protection
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
100.0 milliamperes ac fourth location
Maximum Continuous Load Current Rating Per Pole:
72.0 amperes ac first location
Maximum Continuous Load Current Rating Per Pole:
72.0 amperes ac second location
Maximum Continuous Load Current Rating Per Pole:
72.0 amperes ac third location
Operating Voltage Type And Rating Per Pole In Volts:
240.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
5000.0 ac all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic-hydraulic all locations
Trip Release Characteristic:
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 all locations
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
4 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At each pole
External Actuator Linkage Arrangement:
One, two, three, and four linked
Auxiliary Switch Function And Quantity:
1 alarm
Internal Trip Release Configuration:
Series trip all locations
Thread Size:
0.138 inches
Switch Location And Position Designation:
Internal at pole four
Trip Delay Time In Seconds Per Rated Continuous Current:
2.000 at 200 pct all locations and 22.000 at 200 pct all locations
Inclosure Protection Type For Which Designed:
Corrosion resistant and moisture resistant and shockproof and vibrationproof and fungus resistant
Switch Terminal Type:
Quick disconnect, male
Switch Current Rating And Type In Amps:
10.0 ac and 3.0 dc
Switch Voltage Rating And Type In Volts:
250.0 ac and 50.0 dc
Frequency In Hertz:
60.0 all locations
Unpackaged Unit Weight:
14.800 ounces
Thread Series Designator:
Unc
Terminal Type And Quantity:
8 threaded stud
Item Name:
Thermal Magnetic Trip Breaker
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC