Product Features
High inrush one and two poles only
Detail Specifications
Thread Pitch Diameters:
+0.3503 to 0.3537 inches
Body Style:
Multipole-single actuator type
Bushing Length:
0.380 inches
Body Length:
1.562 inches
Center To Center Distance Between Terminals Parallel To Length:
0.875 inches
Center To Center Distance Between Terminals Parallel To Width:
0.625 inches
Nonturn Device Location:
At 3 oclock and at 9 oclock
Nonturn Device Radius:
0.625 inches
Nonturn Device Length:
0.130 inches
Nonturn Device Diameter:
0.140 inches
Fragility Factor:
Moderately rugged
Mounting Surface To Terminal End Distance:
1.780 inches
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
1 threaded bushing w/panel seal
Storage Type:
General purpose warehouse
Special Handling Feature:
Magnetic
Features Provided:
High inrush protection
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
2.5 amperes ac first location
Maximum Continuous Load Current Rating Per Pole:
2.5 amperes ac second location
Maximum Continuous Load Current Rating Per Pole:
500.0 milliamperes dc third location
Operating Voltage Type And Rating Per Pole In Volts:
115.0 ac second location
Operating Voltage Type And Rating Per Pole In Volts:
115.0 ac first location
Operating Voltage Type And Rating Per Pole In Volts:
28.0 dc third location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
1000.0 ac first location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
1000.0 ac second location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
1000.0 dc third location
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic all locations
Trip Release Characteristic:
Instantaneous third location
Trip Release Characteristic:
Time delay second location
Trip Release Characteristic:
Time delay first location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 all locations
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
1 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At pole two
Internal Trip Release Configuration:
Series trip first location
Internal Trip Release Configuration:
Relay trip third location
Internal Trip Release Configuration:
Series trip second location
Thread Size:
0.375 inches
Trip Delay Time In Seconds Per Rated Continuous Current:
0.070 at 200 pct and 0.700 at 200 pct first location
Trip Delay Time In Seconds Per Rated Continuous Current:
0.070 at 200 pct and 0.700 at 200 pct second location
Inclosure Protection Type For Which Designed:
Hermetically sealed and shock resistant and vibration resistant
Frequency In Hertz:
50.0 or 60.0 first location
Frequency In Hertz:
50.0 or 60.0 second location
Unpackaged Unit Weight:
5.400 ounces
Thread Series Designator:
Unef
Terminal Type And Quantity:
6 wire hook and 2 tab, solder lug
Item Name:
Motor Circuit Protector
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC