Detail Specifications
Thread Pitch Diameters:
+0.4752/+0.4787 inches
Body Style:
Multipole-single actuator type
Bushing Length:
0.625 inches
Body Length:
2.000 inches
Center To Center Distance Between Terminals Parallel To Length:
1.530 inches
Center To Center Distance Between Terminals Parallel To Width:
0.750 inches
Nonturn Device Location:
At 3 oclock and at 9 oclock
Nonturn Device Radius:
0.656 inches
Nonturn Device Length:
0.130 inches
Nonturn Device Diameter:
Between 0.151 inches and 0.161 inches
Switch Contact Arrangement:
Single pole, double throw
Fragility Factor:
Moderately rugged
Mounting Surface To Terminal End Distance:
2.200 inches
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
1 threaded bushing w/panel seal
Storage Type:
General purpose warehouse
Special Handling Feature:
Magnetic
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
1.7 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts:
250.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
3500.0 ac all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic-hydraulic all locations
Trip Release Characteristic:
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
115.0 all locations
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
1 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At pole two
Auxiliary Switch Function And Quantity:
1 alarm
Internal Trip Release Configuration:
Series trip all locations
Thread Size:
0.500 inches
Switch Location And Position Designation:
Internal at pole one
Trip Delay Time In Seconds Per Rated Continuous Current:
7.000 at 125 pct all locations and 90.000 at 125 pct all locations and 3.000 at 150 pct all locations and 40.000 at 150 pct all locations and 1.000 at 200 pct all locations and 12.000 at 200 pct all locations and 0.200 at 400 pct all locations and 3.000 at 400 pct all locations and 0.080 at 600 pct all locations and 1.000 at 600 pct all locations and 0.030 at 800 pct all locations and 0.700 at 800 pct all locations and 0.016 at 1000 pct all locations and 0.300 at 1000 pct all locations
Inclosure Protection Type For Which Designed:
Hermetically sealed and shock resistant and vibration resistant
Switch Terminal Type:
Quick disconnect, male
Switch Current Rating And Type In Amps:
10.0 ac and 5.0 dc
Switch Voltage Rating And Type In Volts:
250.0 ac and 30.0 dc
Frequency In Hertz:
50.0 all locations or 60.0 all locations
Unpackaged Unit Weight:
6.000 ounces
Thread Series Designator:
Un
Terminal Type And Quantity:
4 quick disconnect, male
Item Name:
Motor Circuit Protector
Manufacturer Part Numbers
No other part numbers with same form, fit, and function found.