Detail Specifications
Body Style:
Multipole-multiple actuator type
Body Length:
Between 2.480 inches and 2.500 inches
Center To Center Distance Between Terminals Parallel To Length:
1.940 inches
Center To Center Distance Between Terminals Parallel To Width:
Between 0.735 inches and 0.765 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 2.050 inches and 2.070 inches
Switch Contact Arrangement:
Single pole, double throw
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
Between 0.735 inches and 0.765 inches
Fragility Factor:
Moderately rugged
Boss Height:
0.150 inches
Mounting Surface To Terminal End Distance:
2.625 inches
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
8 threaded hole
Storage Type:
General purpose warehouse
Special Handling Feature:
Magnetic
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
100.0 milliamperes dc fourth location
Maximum Continuous Load Current Rating Per Pole:
100.0 amperes dc first location
Maximum Continuous Load Current Rating Per Pole:
100.0 amperes dc third location
Maximum Continuous Load Current Rating Per Pole:
100.0 milliamperes dc second location
Operating Voltage Type And Rating Per Pole In Volts:
50.0 dc first location
Operating Voltage Type And Rating Per Pole In Volts:
50.0 dc third location
Operating Voltage Type And Rating Per Pole In Volts:
65.0 dc fourth location
Operating Voltage Type And Rating Per Pole In Volts:
65.0 dc second location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
2000.0 dc all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic-hydraulic all locations
Trip Release Characteristic:
Instantaneous third location
Trip Release Characteristic:
Time delay fourth location
Trip Release Characteristic:
Time delay second location
Trip Release Characteristic:
Time delay first location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 all locations
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
4 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At each pole
External Actuator Linkage Arrangement:
One, two, three, and four linked
Internal Trip Release Configuration:
Series trip all locations
Thread Size:
0.138 inches
Switch Location And Position Designation:
Internal at pole four
Trip Delay Time In Seconds Per Rated Continuous Current:
0.024 at 200 pct fourth location
Trip Delay Time In Seconds Per Rated Continuous Current:
0.024 at 200 pct second location
Trip Delay Time In Seconds Per Rated Continuous Current:
0.700 at 200 pct first location and 10.000 at 200 pct first location
Inclosure Protection Type For Which Designed:
Corrosion resistant and moisture resistant and shockproof and vibrationproof and fungus resistant
Switch Terminal Type:
Pin
Switch Current Rating And Type In Amps:
10.0 ac and 10.0 dc
Unpackaged Unit Weight:
14.800 ounces
Thread Series Designator:
Unc
Terminal Type And Quantity:
8 threaded stud
Item Name:
Thermal Magnetic Trip Breaker
Manufacturer Part Numbers
No other part numbers with same form, fit, and function found.