Detail Specifications
Body Style:
Multipole-multiple actuator type
Body Length:
2.490 inches
Center To Center Distance Between Terminals Parallel To Length:
0.667 inches and 1.940 inches
Center To Center Distance Between Terminals Parallel To Width:
0.750 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
2.060 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
0.750 inches
Fragility Factor:
Moderately rugged
Boss Height:
0.150 inches
Mounting Surface To Terminal End Distance:
2.475 inches
Mounting Facility Type And Quantity:
6 threaded hole
Storage Type:
General purpose warehouse
Maximum Continuous Load Current Rating Per Pole:
15.0 amperes ac and 25.0 amperes dc first location
Maximum Continuous Load Current Rating Per Pole:
15.0 amperes ac third location
Maximum Continuous Load Current Rating Per Pole:
15.0 amperes ac second location
Operating Voltage Type And Rating Per Pole In Volts:
120.0 dc first location
Operating Voltage Type And Rating Per Pole In Volts:
277.0 ac second location
Operating Voltage Type And Rating Per Pole In Volts:
277.0 ac third location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
5000.0 ac and 5000.0 dc first location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
5000.0 ac third location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
5000.0 ac second location
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic all locations
Trip Release Characteristic:
Instantaneous first location
Trip Release Characteristic:
Time delay second location
Trip Release Characteristic:
Time delay third location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
138.0 all locations
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
3 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At each pole
External Actuator Linkage Arrangement:
One, two, and three linked
Internal Trip Release Configuration:
Relay trip first location
Internal Trip Release Configuration:
Series trip second location
Internal Trip Release Configuration:
Series trip third location
Thread Size:
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current:
3.000 at 200 pct and 10.000 at 200 pct second location
Trip Delay Time In Seconds Per Rated Continuous Current:
3.000 at 200 pct and 10.000 at 200 pct third location
Inclosure Protection Type For Which Designed:
General purpose
Frequency In Hertz:
400.0 all locations
Thread Series Designator:
Unc
Terminal Type And Quantity:
8 threaded stud
Item Name:
Tri-break Fused Circuit Breaker
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC