#AQB-A101-75H Thermal Magnetic Trip Breaker | Circuit Breakers

AQB-A101-75H

Circuit Breaker

NSN 5925-00-986-7314

DEMIL
Shelf Life
UOM
NIIN
Demil:
NO
Shelf Life:
N/A
UOM:
1 EA
NIIN:
009867314

Detail Specifications

Body Style:
Multipole-single actuator type
Body Length:
6.500 inches
Body Width:
4.125 inches
Body Height:
4.125 inches
Case Material:
Plastic
Center To Center Distance Between Terminals Parallel To Length:
3.938 inches
Center To Center Distance Between Terminals Parallel To Width:
1.375 inches
Unthreaded Mounting Hole Diameter:
0.281 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
3.312 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
3.688 inches
Boss Height:
0.188 inches
Pole Quantity:
3
Mounting Facility Type And Quantity:
4 unthreaded hole
Features Provided:
Adjustable trip release
Maximum Continuous Load Current Rating Per Pole:
75.0 amperes ac all locations and 75.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts:
500.0 ac all locations and 250.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
15000.0 ac all locations and 10000.0 dc all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Thermal-magnetic all locations
Trip Release Characteristic:
Instantaneous all locations and time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
135.0 all locations
Reset Method:
Manual
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
1 toggle
Actuator Function:
Reset
Actuator Position Designation:
At each pole
Adjustable Trip Setting Current Range Per Pole In Amps:
+525.0/+950.0 ac all locations and +525.0/+950.0 dc all locations
Trip Release Ambient Tempurature Rating:
50.0 degrees celsius all locations
Frequency In Hertz:
60.0 all locations
Terminal Type And Quantity:
6 quick disconnect, female
NSN:
5925-00-986-7314
Item Name:
Thermal Magnetic Trip Breaker
Cage Code:
81349

Manufacturer Part Numbers

Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC
Part Number:
MS205083-2BB8
Cage Code:
96906
RNCC:
C
RNVC:
1
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
AC
Part Number:
483505-9
Cage Code:
3B150
RNCC:
3
RNVC:
2
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
483505-9
Cage Code:
49956
RNCC:
5
RNVC:
9
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
458D510G14
Cage Code:
89946
RNCC:
5
RNVC:
2
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
ETN2773
Cage Code:
30086
RNCC:
5
RNVC:
9
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
483505-9
Cage Code:
54X10
RNCC:
5
RNVC:
2
RNAAC:
ZZ
Status:
A
MSDS:
SADC:

  We Guarantee with Every Order

  •   100% Genuine Manufacturers Parts
  •   Every Product thoroughly Inspected
  •   Sales Record Retention of 7 years
  •   Fast Delivery
  •   HAZMAT Certified
  •   Global Shipping

Pricing & Availability

Submit this form for current pricing and availability quote on part number aqb-a101-75h and/or cross reference parts.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:

We do not share or sell your information to anyone.
Privacy | Terms

Catalog Drilldown
--- Electrical And Electronic Equipment Components
------ Circuit Breakers
--------- Circuit Breakers
------------ P/N AQB-A101-75H

New Products Recently updated in circuit breakers

  • 27-10388-1 circuit breaker
    NSN 5925-00-166-3440

    Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height

  • 1536-007-10 circuit breaker
    NSN 5925-00-166-3440

    Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height

  • 314C920G21 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • KA3150 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • 504C336G21 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • BAB1015 circuit breaker
    NSN 5925-00-165-8694

    1 pole quantity, 15.0 amperes ac single location maximum continuous load current rating per pole, 240.0 ac single location operating voltage type and rating per pole in volts


Best-Selling Products A collection of our most popular products

Last Updated: 12/22/2024