Product Features
High inrush pole one only
Product Technical Spec.
Body Style:
Multipole-multiple actuator type
Mounting Slot Width:
0.164 inches
Body Length:
Between 4.740 inches and 4.760 inches
Body Width:
Between 2.038 inches and 2.102 inches
Center To Center Distance Between Terminals Parallel To Length:
Between 3.537 inches and 3.557 inches
Center To Center Distance Between Terminals Parallel To Width:
Between 1.016 inches and 1.036 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 2.740 inches and 2.760 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
Between 1.016 inches and 1.036 inches
Fragility Factor:
Moderately rugged
Boss Height:
Between 0.209 inches and 0.229 inches
Mounting Surface To Terminal End Distance:
Between 3.475 inches and 3.495 inches
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
4 threaded hole and 4 slot
Storage Type:
General purpose warehouse
Special Handling Feature:
Magnetic
Features Provided:
High inrush protection
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
20.0 amperes dc second location
Maximum Continuous Load Current Rating Per Pole:
5.0 amperes ac first location
Operating Voltage Type And Rating Per Pole In Volts:
115.0 ac first location
Operating Voltage Type And Rating Per Pole In Volts:
35.0 dc second location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
5000.0 ac first location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
5000.0 dc second location
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic all locations
Trip Release Characteristic:
Instantaneous second location
Trip Release Characteristic:
Time delay first location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 all locations
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
2 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At each pole
External Actuator Linkage Arrangement:
One and two linked
Internal Trip Release Configuration:
Series trip first location
Internal Trip Release Configuration:
Series trip w/auxiliary load terminal second location
Thread Size:
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current:
2.000 at 200 pct first location and 10.000 at 200 pct first location
Inclosure Protection Type For Which Designed:
Fungus resistant and moisture resistant
Frequency In Hertz:
60.0 all locations
Unpackaged Unit Weight:
1.300 pounds
Thread Series Designator:
Unc
Terminal Type And Quantity:
5 threaded stud
Item Name:
Breaker,circuit
Cross Referenced Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC