Technical Specifications of NSN
Body Style:
Multipole-multiple actuator type
Mounting Slot Width:
0.164 inches
Body Length:
3.544 inches
Center To Center Distance Between Terminals Parallel To Length:
3.546 inches
Center To Center Distance Between Terminals Parallel To Width:
1.032 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
2.750 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
1.032 inches
Boss Height:
0.218 inches
Mounting Surface To Terminal End Distance:
2.609 inches
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
8 threaded hole and 8 slot
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
0.0 amperes ac fourth location
Maximum Continuous Load Current Rating Per Pole:
100.0 amperes ac first location
Maximum Continuous Load Current Rating Per Pole:
100.0 amperes ac second location
Maximum Continuous Load Current Rating Per Pole:
100.0 amperes ac third location
Operating Voltage Type And Rating Per Pole In Volts:
115.0 ac fourth location
Operating Voltage Type And Rating Per Pole In Volts:
240.0 ac second location
Operating Voltage Type And Rating Per Pole In Volts:
240.0 ac first location
Operating Voltage Type And Rating Per Pole In Volts:
240.0 ac third location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
5000.0 ac all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic-hydraulic all locations
Trip Release Characteristic:
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
150.0 all locations
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
4 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At each pole
External Actuator Linkage Arrangement:
One, two, three, and four linked
Internal Trip Release Configuration:
Series trip first location
Internal Trip Release Configuration:
Series trip second location
Internal Trip Release Configuration:
Series trip third location
Internal Trip Release Configuration:
Shunt trip fourth location
Thread Size:
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current:
40.000 at 200 pct first location and 105.000 at 200 pct first location
Trip Delay Time In Seconds Per Rated Continuous Current:
40.000 at 200 pct second location and 105.000 at 200 pct second location
Trip Delay Time In Seconds Per Rated Continuous Current:
40.000 at 200 pct third location and 105.000 at 200 pct third location
Trip Delay Time In Seconds Per Rated Continuous Current:
0.530 at 200 pct fourth location and 1.500 at 200 pct fourth location
Inclosure Protection Type For Which Designed:
Dustproof
Frequency In Hertz:
400.0 all locations
Thread Series Designator:
Unc
Terminal Type And Quantity:
9 threaded stud
Item Name:
Breaker Assembly
Other Related Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC